Re: [CAD_CAM_EDM_DRO] Zeepower
Posted by
Darrell
on 2000-09-24 19:52:37 UTC
Dave,
The Bridgeport system uses the most power while at rest and
less the faster it goes. A function of the R/L type drive.
All three axes use the same drivers and power supplies.
Average for a properly set drive is 8 amps at 9 to 11 volts.
Hope this helps.
Darrell -.-. --.- -.-. --.- -.. . .-
.-.. --... -.. ---
http://www.machinemaster.com
The Bridgeport system uses the most power while at rest and
less the faster it goes. A function of the R/L type drive.
All three axes use the same drivers and power supplies.
Average for a properly set drive is 8 amps at 9 to 11 volts.
Hope this helps.
Darrell -.-. --.- -.-. --.- -.. . .-
.-.. --... -.. ---
http://www.machinemaster.com
----- Original Message -----
From: "dave engvall" <dengvall@...>
> Hi everyone:
>
> How much power does BP use to move the spindle axis?
i.e.
> in Z not it C :-)
>
> Dave
>
Discussion Thread
dave engvall
2000-09-24 09:36:52 UTC
Zeepower
Darrell
2000-09-24 19:52:37 UTC
Re: [CAD_CAM_EDM_DRO] Zeepower
Jon Elson
2000-09-24 22:08:08 UTC
Re: [CAD_CAM_EDM_DRO] Zeepower