3phase & Re: 50uF + suplus motor run caps sources???
Posted by
Lee Studley
on 2000-09-30 12:29:56 UTC
Alan,
You are correct, caps in series double or 'add' w/ respect
to voltage rating and follow the
Ctotal= 1/(1/c1 + 1/c2 + 1/c3...)
or inverse sum of inverses equation.
-Lee
--- In CAD_CAM_EDM_DRO@egroups.com, Alan Marconett KM6VV <KM6VV@a...>
wrote:
You are correct, caps in series double or 'add' w/ respect
to voltage rating and follow the
Ctotal= 1/(1/c1 + 1/c2 + 1/c3...)
or inverse sum of inverses equation.
-Lee
--- In CAD_CAM_EDM_DRO@egroups.com, Alan Marconett KM6VV <KM6VV@a...>
wrote:
> Darrell,
>
> Wouldn't that be 3 uF @ 472v ?
>
> Alan
>
> Darrell wrote:
> >
> > If you connect then in series, 2 6 uF 236 vac caps become
> > one 472 vac 6 uF caps.
> > Darrell
> >
Discussion Thread
Alan Marconett KM6VV
2000-09-30 11:25:18 UTC
Re: [CAD_CAM_EDM_DRO] 3phase & Re: 50uF + suplus motor run caps sources???
Lee Studley
2000-09-30 12:29:56 UTC
3phase & Re: 50uF + suplus motor run caps sources???
Darrell
2000-09-30 15:00:30 UTC
Re: [CAD_CAM_EDM_DRO] 3phase & Re: 50uF + suplus motor run caps sources???