Thanks, I have 3 Toroidal Transformers and 3 beer can sized caps.
Those take a bit of space. I have two enclosures one more suited
for the power supply and the other more suited for the Gecko drives
and any solid state relays necessary. Keeping the two sperated
also keeps power wiring away from control wiring. I don't see much
if any opposition, so I'll probably go with that using the 470uf Caps
on the Gecko drives.
Marty
Those take a bit of space. I have two enclosures one more suited
for the power supply and the other more suited for the Gecko drives
and any solid state relays necessary. Keeping the two sperated
also keeps power wiring away from control wiring. I don't see much
if any opposition, so I'll probably go with that using the 470uf Caps
on the Gecko drives.
Marty
On 18 Jun 2001, at 18:58, HighTech wrote:
> I have talked with the Gecko engineers about this subject. There is no
> problem with the power transformer being in the same cabinet as the
> Gecko drives. The main thing you want to watch is getting the power
> lines to close to the stepper or servo line keep the bundles as far
> from each other as possible. Remember your inverse square law. Tie
> all power grounds to a single point. The main cap is a good spot. No
> ground loops. Run the power lines from the main cap to each drive not
> jump from one drive to the next. Hope this helps. Derek B.
>
>
> > Re: My Bridgeport Series I conversion...
> >
> > I have found a nice enclosure..it would be tight to put everything
> > into it, but I think I could do it being creative. But I have a
> > smaller cabinet that I thought I could put the Gecko drives in and
> > solid state relays, the electronics basically.
> >
> > What I'm wondering, would it be ok and adviseable to keep the
> > power supply in its own enclosure and the electronics in their
> > seperate enclosure. In reading the Gecko white papers, if there is
> > more than 18:" of wire between the power supply and the drive, then
> > a 470uf cap must be used. Which isn't a problem
> >
> > Anything else I should be aware of?
> > The power supply will be 3 44VAC 9 amp Toroidal transformers,
> > bridges and 15000uf caps. ( 3 seperate supplies, one for each
> > drive/stepper)
> >
> > Thanks!
> > Marty
> >
> > Addresses:
> > FAQ: http://www.ktmarketing.com/faq.html
> > FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> >
> > Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
> > Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> > Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> > List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com,
> > wanliker@... Moderator: jmelson@...
> > timg@... [Moderator] URL to this page:
> > http://groups.yahoo.com/group/CAD_CAM_EDM_DRO bill, List Manager
> >
> >
> >
> > Your use of Yahoo! Groups is subject to
> > http://docs.yahoo.com/info/terms/
> >
> >
> >
>
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
> Moderator: jmelson@... timg@... [Moderator]
> URL to this page: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO bill,
> List Manager
>
>
>
> Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
>
>
Discussion Thread
garyswindell@h...
2001-06-06 08:17:16 UTC
Are there any reasons NOT to use flood cooling?
David M. Munro
2001-06-06 08:46:30 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Tim Goldstein
2001-06-06 08:51:26 UTC
RE: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
dougrasmussen@c...
2001-06-06 09:03:20 UTC
Re: Are there any reasons NOT to use flood cooling?
Smoke
2001-06-06 12:05:39 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Robert Allen & Marsha Camp
2001-06-07 15:54:11 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Doug Harrison
2001-06-07 18:15:29 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Jon Elson
2001-06-07 22:09:58 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Tim Goldstein
2001-06-07 22:21:51 UTC
RE: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
ptengin@a...
2001-06-08 02:11:17 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Jon Elson
2001-06-08 18:03:08 UTC
Re: [CAD_CAM_EDM_DRO] Are there any reasons NOT to use flood cooling?
Marty Escarcega
2001-06-17 06:41:53 UTC
Power Supply & Drives in the same cabinet or seperate
HighTech
2001-06-18 17:54:40 UTC
Re: [CAD_CAM_EDM_DRO] Power Supply & Drives in the same cabinet or seperate
Marty Escarcega
2001-06-18 19:31:01 UTC
Re: [CAD_CAM_EDM_DRO] Power Supply & Drives in the same cabinet or seperate