Re: [CAD_CAM_EDM_DRO] Incremental velocity BDI EMC
Posted by
Jon Elson
on 2001-08-08 21:51:07 UTC
Stephen Goldsmith wrote:
can
be set to optimize each configuration. There is a default and a maximum
velocity parameter, and a default and maximum acceleration. You set these
(in user units/second and units/second^2) to the value that works reliably
on
your machine. unfortunately, there is only one setting for the whole
system,
it can't be set differently for each axis.
If you are asking how to write the 'G-code' for this, you don't have to.
ALL
moves are made with the default acceleration up to the programmed feed
rate.
Jon
> Hello AllThere is an ".ini" file that has several hundred lines of parameters which
>
> Another question!
>
> How does one set up emc to start the stepper motion speed slow and
> accelerate up to the desired speed as default, thus minimizing missed
> steps at the stepper motor?
can
be set to optimize each configuration. There is a default and a maximum
velocity parameter, and a default and maximum acceleration. You set these
(in user units/second and units/second^2) to the value that works reliably
on
your machine. unfortunately, there is only one setting for the whole
system,
it can't be set differently for each axis.
If you are asking how to write the 'G-code' for this, you don't have to.
ALL
moves are made with the default acceleration up to the programmed feed
rate.
Jon
Discussion Thread
Stephen Goldsmith
2001-08-08 10:56:27 UTC
Incremental velocity BDI EMC
Jon Elson
2001-08-08 21:51:07 UTC
Re: [CAD_CAM_EDM_DRO] Incremental velocity BDI EMC