Hi all,
Thanks a million for all your info... have yet another question. How
hard would it be to control a relay from the parallel port; using a G-
code command. I am trying to use a plasma torch; and upon sending the
signal to the relay, it'll turn the plasma on.
Any thoughts?


Chris

Several EMC users have grabbed one of the coolant commands (m7, m8, m9)
and have used them to turn on other stuff. You could also use the spindle
command. You would need a second parport if you use steppers for axis
motion.

HTH

RayH

Discussion Thread

cclough@x... 2001-11-18 18:28:33 UTC Relay controlled by parallel Alan Marconett KM6VV 2001-11-18 18:54:29 UTC Re: [CAD_CAM_EDM_DRO] Relay controlled by parallel cncdxf@a... 2001-11-18 18:58:57 UTC Re: Relay controlled by parallel Ray 2001-11-19 06:42:54 UTC Relay controlled by parallel Tim Goldstein 2001-11-19 07:34:27 UTC RE: [CAD_CAM_EDM_DRO] Relay controlled by parallel Chris Clough 2001-11-20 10:09:01 UTC Greasing linear rails Sven Peter 2001-11-20 17:39:41 UTC Re: [CAD_CAM_EDM_DRO] Greasing linear rails Chris Clough 2001-12-04 14:54:22 UTC RE: [CAD_CAM_EDM_DRO] Relay controlled by parallel