Re: wiring for 4-wire motor & Gecko drive

Posted by studleylee
on 2002-02-09 18:40:32 UTC
The gound wire is really extra. You can leave it unconnected, or put
it to either ground. It just sounds like it is for shielding the case
or providing a protective ground in case the stepper is bolted to
a chassis or whatever and the operator might touch it. This would only
be a problem if the chassis etc become 'hot' due to a frayed wire etc.
Leaving it unconnected wont affect operation.
-Lee


--- In CAD_CAM_EDM_DRO@y..., "Rick Miller" <apollo@a...> wrote:
> Hi,
> I'm wiring up a 4 wire step motor to a Gecko 201A. The motor
has 4 wires
> (A, -A, B, -B), and a "ground" wire.
> Does anyone know if the "ground" wire from the motor should be
connected
> to the "Power Ground" wire on the Gecko drive, or is it to be
connected to
> an "earth ground"?
>
> Thanks,
> Rick