staerlucas@... wrote:
Is it an AC induction motor, or permanent magnet motor?
I have a Westwind air bearing spindle that I have got running up to
400 Hz (24000 RPM) on a standard Magnetek VFD. AC Tech has
a VFD that goes to 1000 Hz, that would get you up to 60,000 RPM.
Because of the low inductance of these motors, you have to add
a series inductor on each of the 3 motor wires.
Jon
>HI !Do you have any more info on this spindle? What is AB, air bearing?
>
>I've got a Spintec AB Spindle but I have not the the driver !
>
>
>
>I'am looking for an integrated circuit or a schematic for the spindle driver.
>
>
Is it an AC induction motor, or permanent magnet motor?
I have a Westwind air bearing spindle that I have got running up to
400 Hz (24000 RPM) on a standard Magnetek VFD. AC Tech has
a VFD that goes to 1000 Hz, that would get you up to 60,000 RPM.
Because of the low inductance of these motors, you have to add
a series inductor on each of the 3 motor wires.
Jon