RE: [CAD_CAM_EDM_DRO] Re: Testing servos
Posted by
Dan Mauch
on 2003-10-20 06:46:24 UTC
One other vital test on a PMDC motor is to connect a multimeter to one
of the wires/terminals. Set the meter to read continuity, then check to
the motor frame that there is an open circuit. Then check the other lead
to the motor frame. Both should read open. The reason for this is some
so called servo motors have one of their leads connected to the motor
frame.
Dan
of the wires/terminals. Set the meter to read continuity, then check to
the motor frame that there is an open circuit. Then check the other lead
to the motor frame. Both should read open. The reason for this is some
so called servo motors have one of their leads connected to the motor
frame.
Dan
Discussion Thread
GRautoHP@a...
2003-10-18 10:50:34 UTC
Testing servos
caudlet
2003-10-18 16:24:11 UTC
Re: Testing servos
balsaman_cnc
2003-10-18 22:45:38 UTC
Re: Testing servos
Jon Elson
2003-10-18 22:58:57 UTC
Re: [CAD_CAM_EDM_DRO] Testing servos
bitnick78
2003-10-19 14:03:59 UTC
Re: Testing servos
Jon Elson
2003-10-19 22:19:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: Testing servos
Dan Mauch
2003-10-20 06:46:24 UTC
RE: [CAD_CAM_EDM_DRO] Re: Testing servos