Not if you have good dynamic current control and the motor insulation is
good enough to handle the voltage spikes it actually sees.

cvl

----- Original Message -----
From: <john@...>
To: <CAD_CAM_EDM_DRO@egroups.com>
Sent: Thursday, August 10, 2000 4:16 PM
Subject: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim


> Sorry to butt in on this thread but Mariss's original reply is copied
> below.
> Mariss states
> >" To get the maximum power from a 7A, 80V drive, pick a 7 Amp, 4
> >volt motor. "
>
> Surely a 4V motor running on 80v supply will burn out.
> Am I missing something here ?
>
> > ----- Original Message -----
> > From: Mariss Freimanis <geckohall@h...>
> > To: <CAD_CAM_EDM_DRO@egroups.com>
> > Sent: Monday, June 12, 2000 6:14 PM
> > Subject: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
> > > Now to bring this all together. Size 42 motors I'm sure you have
> > > noticed have much higher detent torque than size 34 or 23 motors.
> > > This is the reason why size 42 motors run out of steam before the
> > > smaller motors do. Second, for the same amperage, a size 42 motor
> > has
> > > much higher inductance and rated voltage than a 34 motor. That
> means
> > > they come into their own at much higher supply voltages; 160 to
> 200
> > > VDC. To get the maximum power from a 7A, 80V drive, pick a 7 Amp,
> 4
> > > volt motor. This will be either a 4 stack 34 or a single stack 42.
> > > For peak power, gear the motor to run just past the speed where
> the
> > > drive ceases chopping (i.e. current limiting).
> > >
>
>
>
>
>
> Welcome to CAD_CAM_EDM_DRO@...,an unmoderated list for the
discussion of shop built systems, for CAD, CAM, EDM, and DRO.
>
> Addresses:
> Post message: CAD_CAM_EDM_DRO@egroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@egroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@egroups.com
> List owner: CAD_CAM_EDM_DRO-owner@egroups.com, wanliker@...
> Moderator: jmelson@... [Moderator]
> URL to this page: http://www.egroups.com/group/CAD_CAM_EDM_DRO
> FAQ: http://www.ktmarketing.com/faq.html
> bill,
> List Manager
>
>

Discussion Thread

Doug Harrison 2000-06-12 14:35:16 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim Mariss Freimanis 2000-06-12 16:14:32 UTC Re: Gecko and Anaheim James Cullins 2000-08-10 15:06:25 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim john@m... 2000-08-10 15:16:51 UTC Re: Gecko and Anaheim Jon Elson 2000-08-10 15:36:47 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim Charles VanLeeuwen 2000-08-10 19:38:07 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim Mariss Freimanis 2000-08-10 21:04:06 UTC Re: Gecko and Anaheim James Cullins 2000-08-11 06:19:33 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim JanRwl@A... 2000-08-12 20:10:47 UTC Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim