Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
Posted by
Charles VanLeeuwen
on 2000-08-10 19:38:07 UTC
Not if you have good dynamic current control and the motor insulation is
good enough to handle the voltage spikes it actually sees.
cvl
good enough to handle the voltage spikes it actually sees.
cvl
----- Original Message -----
From: <john@...>
To: <CAD_CAM_EDM_DRO@egroups.com>
Sent: Thursday, August 10, 2000 4:16 PM
Subject: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
> Sorry to butt in on this thread but Mariss's original reply is copied
> below.
> Mariss states
> >" To get the maximum power from a 7A, 80V drive, pick a 7 Amp, 4
> >volt motor. "
>
> Surely a 4V motor running on 80v supply will burn out.
> Am I missing something here ?
>
> > ----- Original Message -----
> > From: Mariss Freimanis <geckohall@h...>
> > To: <CAD_CAM_EDM_DRO@egroups.com>
> > Sent: Monday, June 12, 2000 6:14 PM
> > Subject: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
> > > Now to bring this all together. Size 42 motors I'm sure you have
> > > noticed have much higher detent torque than size 34 or 23 motors.
> > > This is the reason why size 42 motors run out of steam before the
> > > smaller motors do. Second, for the same amperage, a size 42 motor
> > has
> > > much higher inductance and rated voltage than a 34 motor. That
> means
> > > they come into their own at much higher supply voltages; 160 to
> 200
> > > VDC. To get the maximum power from a 7A, 80V drive, pick a 7 Amp,
> 4
> > > volt motor. This will be either a 4 stack 34 or a single stack 42.
> > > For peak power, gear the motor to run just past the speed where
> the
> > > drive ceases chopping (i.e. current limiting).
> > >
>
>
>
>
>
> Welcome to CAD_CAM_EDM_DRO@...,an unmoderated list for the
discussion of shop built systems, for CAD, CAM, EDM, and DRO.
>
> Addresses:
> Post message: CAD_CAM_EDM_DRO@egroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@egroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@egroups.com
> List owner: CAD_CAM_EDM_DRO-owner@egroups.com, wanliker@...
> Moderator: jmelson@... [Moderator]
> URL to this page: http://www.egroups.com/group/CAD_CAM_EDM_DRO
> FAQ: http://www.ktmarketing.com/faq.html
> bill,
> List Manager
>
>
Discussion Thread
Doug Harrison
2000-06-12 14:35:16 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
Mariss Freimanis
2000-06-12 16:14:32 UTC
Re: Gecko and Anaheim
James Cullins
2000-08-10 15:06:25 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
john@m...
2000-08-10 15:16:51 UTC
Re: Gecko and Anaheim
Jon Elson
2000-08-10 15:36:47 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
Charles VanLeeuwen
2000-08-10 19:38:07 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
Mariss Freimanis
2000-08-10 21:04:06 UTC
Re: Gecko and Anaheim
James Cullins
2000-08-11 06:19:33 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim
JanRwl@A...
2000-08-12 20:10:47 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko and Anaheim