How to Measure Backlash on a CNC Machine
If your CNC machine is leaving tiny flat spots on circles or missing dimensions by a hair when changing directions, you likely have mechanical backlash. Measuring backlash on a ball screw axis only takes a few minutes with a standard dial indicator—as long as you avoid one common setup mistake that can give you a false zero.
In this guide, I’ll walk through the exact setup and step-by-step procedure I use to measure backlash on a 20mm ball screw axis.
What Is Backlash (and Why Does It Happen)?
Backlash is the tiny amount of "lost motion" or mechanical play that occurs when an axis reverses direction. Instead of the carriage moving the instant the motor starts turning the other way, the screw rotates a fraction of a turn to take up microscopic clearances before the table actually begins to move.
On a ball screw CNC axis, this play usually comes from a few normal mechanical tolerances:
- Ball Nut Clearance: Unless you are running an expensive preloaded double-nut setup, a single ball nut needs a tiny amount of internal clearance so the recirculating steel balls can roll freely without binding.
- Support Bearings: Slight axial play in the fixed-end angular contact bearings (such as a BK15 bearing block) allows the entire screw to shift back and forth by a few ten-thousandths of an inch under load.
- Motor Coupler & Mounts: Tiny amounts of flex in a spider coupler or slight settling in bearing block fasteners can add to the deadband on reversal.
While a small amount of backlash is completely normal on any hobby or prosumer CNC machine, measuring it lets you confirm your hardware is tight.
Setup & Equipment
To get an accurate reading, every component holding your indicator must be completely rigid so flex doesn't disguise itself as axis play. Here is how my setup is arranged (matching the labels in the diagram above):
- Steel Vise (rigid and magnetic): Because my CNC router has an MDF spoilboard with aluminum T-tracks, a magnetic base won't stick directly to the bed. Clamping a heavy steel machine vise to the table provides a rock-solid, magnetic surface.
- Magnet Base (switched on): Locks firmly onto the flat steel surface of the vise. Once switched on, give it a gentle tug to confirm there is zero rocking.
- Articulating Arm: A central-locking articulating arm positions the gauge right at spindle height. After aligning the indicator, tighten the black locking knob firmly so the joints cannot creep during direction reversals.
- Dial Indicator: A standard plunger-style dial indicator (
0.001"or0.0005"resolution works well). - Plunger: Aligned as straight and parallel to the X-axis travel as possible to prevent cosine error.
- Collet Nut (smooth surface): The plunger tip rests squarely against the flat side of the ER collet nut (or a smooth gauge pin chucked into the collet). Avoid touching the spiral flutes of an end mill, which can catch or deflect the tip.
The Golden Rule of Setup: Keep the Plunger Engaged
Before zeroing anything out, there is one critical detail to get right: the Plunger must stay in physical contact with the Collet Nut throughout the entire test.
If you only preload the indicator by 2mm and then jog the axis away by 5mm, the plunger will hit its internal extension limit and lose contact. When the axis returns, it impacts the stationary plunger tip, which can shift your magnet base or introduce reading errors.
The Fix:
- Preload the Dial Indicator to the middle of its travel range (for example, compress a 10mm travel indicator by about 5mm).
- Use a small test stroke—
±1mmor±2mmis plenty to take up any mechanical slack without risking losing contact or bottoming out the indicator.
Step-by-Step Measurement Procedure
- Preload the Plunger: Jog the X-axis into the dial indicator until the Plunger is compressed roughly halfway through its travel against the Collet Nut.
- Zero Your Axis & Indicator: Set your machine's X-axis work coordinate to '0', and rotate the bezel on your Dial Indicator so the needle points directly to
0. - Test the Positive Approach (
+to0):- Jog the X-axis to
+2mm. - Jog the X-axis back to
0mmin a single move. - Record Reading A: Note the exact value on the dial indicator. (If you originally preloaded the indicator by moving in the negative direction, this move approaches
0from the same side and should read0.)
- Jog the X-axis to
- Test the Negative Approach (
-to0):- Jog the X-axis to
-2mm. - Jog the X-axis back to
0mmin a single move. - Record Reading B: Note the exact value on the dial indicator.
- Jog the X-axis to
- Calculate Your Backlash: Find the absolute difference between your two readings:
$$\text{Backlash} = |\text{Reading A} - \text{Reading B}|$$
Why This Works
By approaching 0mm from the positive side in Step 3 and from the negative side in Step 4, you force the ball nut to seat against opposite sides of the screw's raceway. Subtracting the two readings isolates the exact deadband (lost motion) upon direction reversal—eliminating any guesswork about which way you preloaded the indicator at the start.
What Is a "Good" Backlash Number?
On my 20mm ball screw setup, this test measured 0.0005" (0.0127mm) of backlash. Here is how to interpret your own results:
- 0.0005" to 0.002" (0.012mm to 0.05mm): Completely normal for standard rolled ball screws (like C7-grade SFU2005 or SFU2010 screws) with a single ball nut. For woodworking, plastics, and general aluminum milling,
0.0005"is rock-solid. - 0.0001" to 0.0003" (0.0025mm to 0.008mm): Typical for precision-ground screws or preloaded double-nut assemblies.
- Over 0.003" (0.075mm+): Worth investigating. Check the locknut on your fixed-end bearing block (like a BK15), verify your motor coupler set screws are tight, and inspect your ball nut mounting bolts before relying on software compensation.