CAD CAM EDM DRO - Yahoo Group Archive

Re: Transformer True or False?

on 2000-12-18 09:22:59 UTC
Joe,

I've always found three phase transformers to be fairly expensive.
Instead, I use two inexpensive single phase transformers hooked up in
an open-delta configuration. Several of my 440V machines are running
this way off 220V power.

Check with any transformer company they'll have the details of the
hookup.

Doug



--- In CAD_CAM_EDM_DRO@egroups.com, Joe Vicars <jvicars@c...> wrote:
> I called All Phase asking for a 3 phase 240-480 step up
> transformer. They said any transformer can be a step up
transformer,
> just hook it up backwards.
> Is this correct??
> I've been hunting for a "step up" for weeks.

Discussion Thread

Joe Vicars 2000-12-18 06:52:52 UTC Transformer True or False? Spehro Pefhany 2000-12-18 06:55:11 UTC Re: [CAD_CAM_EDM_DRO] Transformer True or False? dougrasmussen@c... 2000-12-18 09:22:59 UTC Re: Transformer True or False? Smoke 2000-12-18 09:33:08 UTC Re: [CAD_CAM_EDM_DRO] Transformer True or False? JanRwl@A... 2000-12-18 18:18:29 UTC Re: [CAD_CAM_EDM_DRO] Transformer True or False? JanRwl@A... 2000-12-18 18:25:58 UTC Re: [CAD_CAM_EDM_DRO] Re: Transformer True or False?