CAD CAM EDM DRO - Yahoo Group Archive

Re: Multiple G320s

Posted by carlcnc@e...
on 2001-04-27 17:47:18 UTC
--- In CAD_CAM_EDM_DRO@y..., mariss92705@y... wrote:
> Hi,
>
> I've come up with a simple circuit for operating multiple
G320/G340s.
> Here's what it does:
>
> 1) If one drive "faults" it automatically shuts down all the others.
> 2) It sends an opto-isolated signal back to the PC of a "fault"
> 3) It sends a signal back to the PC when the drives are ready to go.
> 4) A PC can enable or reset all drives via an opto-isolated input.
> 5) A single contol wire goes out to all the drives to do this.
> 6) You don't have to hold an "enable" switch for 5 sec.
>
> If anyone is interested, contact me off-list and I will e-mail you
> the circuit diagram, or with permission I can post it in the "files"
> section as a .pdf.
>
> Mariss

Discussion Thread

mariss92705@y... 2001-04-27 17:32:10 UTC Multiple G320s carlcnc@e... 2001-04-27 17:46:58 UTC Re: Multiple G320s carlcnc@e... 2001-04-27 17:47:18 UTC Re: Multiple G320s Tim Goldstein 2001-04-27 21:30:00 UTC RE: [CAD_CAM_EDM_DRO] Multiple G320s Robert Allen & Marsha Camp 2001-04-28 16:46:44 UTC Re: [CAD_CAM_EDM_DRO] Multiple G320s mariss92705@y... 2001-04-28 17:54:10 UTC Re: Multiple G320s wanliker@a... 2001-04-29 22:22:22 UTC Re: [CAD_CAM_EDM_DRO] Multiple G320s