CAD CAM EDM DRO - Yahoo Group Archive

Camtronics Controller/Motor Temp

Posted by phil
on 2001-06-20 19:45:52 UTC
I'm using the small Camtronics Controller (2Amp) with EMC and am slightly worried about my motor temperatures.

I checked the current being supplied in hold and step states and was surprised to see that when EMC is running a program it has the motors that aren't actually being stepped locked with the full current. If I pause the program this still remains so, but if I disconnect the parallel cable between the PC and the controller the current falls back to the setting I selected using the HOLD potentiometer.

Is this the correct behavior ?

Thanks Phil


[Non-text portions of this message have been removed]

Discussion Thread

phil 2001-06-20 19:45:52 UTC Camtronics Controller/Motor Temp Jon Elson 2001-06-20 21:53:28 UTC Re: [CAD_CAM_EDM_DRO] Camtronics Controller/Motor Temp