Re: [CAD_CAM_EDM_DRO] Servo motor maximum voltage rating
Posted by
Peter Seddon
on 2001-10-26 02:01:50 UTC
Higher speed, but under any sort of load possible flash over at the
brushgear and consequent damage. Motor would definitely not be able to
deliver full load at this higher speed.
Regards Peter
brushgear and consequent damage. Motor would definitely not be able to
deliver full load at this higher speed.
Regards Peter
----- Original Message -----
From: <npalen@...>
To: <CAD_CAM_EDM_DRO@yahoogroups.com>
Sent: Friday, October 26, 2001 3:33 AM
Subject: [CAD_CAM_EDM_DRO] Servo motor maximum voltage rating
> Hello--I'm running some small pitman servo motors rated at 30 volts
> on a 24 volt power supply. What happens if I switch to a 48 volt
> supply to get better performance? Instant destruction?
> Thanks.
> Nelson
>
>
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
> Moderator: jmelson@... timg@... [Moderator]
> URL to this page: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> bill,
> List Manager
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>
>
>
Discussion Thread
npalen@n...
2001-10-25 19:37:45 UTC
Servo motor maximum voltage rating
Peter Seddon
2001-10-26 02:01:50 UTC
Re: [CAD_CAM_EDM_DRO] Servo motor maximum voltage rating
npalen@n...
2001-10-26 05:09:16 UTC
Re: Servo motor maximum voltage rating
mariss92705@y...
2001-10-26 09:17:08 UTC
Re: Servo motor maximum voltage rating
Peter Seddon
2001-10-27 03:02:20 UTC
Re: [CAD_CAM_EDM_DRO] Re: Servo motor maximum voltage rating
mariss92705@y...
2001-10-27 10:50:00 UTC
Re: Servo motor maximum voltage rating
Jon Elson
2001-10-27 21:51:03 UTC
Re: [CAD_CAM_EDM_DRO] Re: Servo motor maximum voltage rating