CAD CAM EDM DRO - Yahoo Group Archive

Re: Motor and Power Supply Questions

on 2002-06-06 17:53:42 UTC
ummm, I guess "cus I said so" ain't gonna cut it.

Series does not requre matched, as far as my limited knoledge allows.

Parallel does.

Seems like I should have had that second cup of coffee after all.

Dave




--- In CAD_CAM_EDM_DRO@y..., "Carol & Jerry Jankura"
<jerry.jankura@s...> wrote:
> Out of curiosity, why would matched transformers be required for a
SERIES
> connection. (I understand the need for a parallel connection, but
would
> expect that except for having to use the lowest rated transformer
as your
> maximum current, that there would be no similar problem with the
series
> connected transformers)
>
> -- Jerry
>
>
> |Hi Ralph,
> |
> |If you are going for the maximum, you should be able to get EXACTLY
> |THE SAME transformers and connect them in series. This would
double
> |the voltage output. MATCHED transformers are a must.

Discussion Thread

rawen2 2002-06-05 20:49:26 UTC Motor and Power Supply Questions turbulatordude 2002-06-06 07:44:07 UTC Re: Motor and Power Supply Questions hugo_cnc 2002-06-06 07:56:51 UTC Re: Motor and Power Supply Questions Carol & Jerry Jankura 2002-06-06 08:55:19 UTC RE: [CAD_CAM_EDM_DRO] Re: Motor and Power Supply Questions ian15538 2002-06-06 10:28:18 UTC Re: Motor and Power Supply Questions Alan Marconett KM6VV 2002-06-06 14:48:00 UTC Re: Motor and Power Supply Questions JanRwl@A... 2002-06-06 16:55:09 UTC Re: [CAD_CAM_EDM_DRO] Re: Motor and Power Supply Questions turbulatordude 2002-06-06 17:53:42 UTC Re: Motor and Power Supply Questions bjammin@i... 2002-06-07 04:23:36 UTC Re: [CAD_CAM_EDM_DRO] Re: Motor and Power Supply Questions