Re: Update: 0 - 10VDC to 4 - 20 mA conversion
Posted by
andyolney
on 2002-08-07 11:42:57 UTC
>Alan - Check you manual some more! My VDF works exactly this way.
> Unfortunately my direction problem won't be quite as
> simple. The control has a "spindle on" relay and then a
> separate "reverse" relay.... I'll have to change that to
> two distinct contact... FWD and REVERSE. With luck I'll
> have some spare contacts with which to accomplish this.
> If not I'll twiddle a little. But that is all fairly
> easy.
>
One contact turns on the drive and another contact determines the
direction. Yours may have the option to do this. Andy
Discussion Thread
flyspeck1@a...
2002-08-07 09:35:51 UTC
Update: 0 - 10VDC to 4 - 20 mA conversion
andyolney
2002-08-07 11:42:57 UTC
Re: Update: 0 - 10VDC to 4 - 20 mA conversion