CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Re: OK... Wall Wart Bad Idea for someone who would have to ask what size!

Posted by Keith Bowers
on 2002-08-22 09:39:52 UTC
Some things to consider when using PC supplies for other things.
First - From what I have read here and there, in most cases only the +5 is
regulated, the others are just full wave rectified off additional windings
on the transformer. At least in some supplies none of the voltages will be
correct unless there is a certain minimum load on the +5, and I don't know
what that load must be.
Second - Many of these PC supplies are totally intolerant of shorts. The
power supply semiconductors to an outstanding job of protecting the fuse
(personal experience).
Third - The "modern" ATX-style supplies won't start sitting bare on the
bench; you have to connect at least a couple of pins together and I don't
know offhand which ones.

You are probably better off to stick with a non-PC supply from BG Micro or
one of the other surplus dealers. Those supplies are generally current
limited and will stand up to all sorts of abuse.

----- Original Message -----
From: "ksprayberry428" <kellys@...>
To: <CAD_CAM_EDM_DRO@yahoogroups.com>
Sent: Thursday, August 22, 2002 12:07 PM
Subject: [CAD_CAM_EDM_DRO] Re: OK... Wall Wart Bad Idea for someone who
would have to ask what size!


> I believe someone said it would. I used an old computer case to mount
> everything in. I will check the power supply
> Kelly
>
> snip<

Discussion Thread

ksprayberry428 2002-08-22 04:59:31 UTC OK... Wall Wart Bad Idea for someone who would have to ask what size! caudlet 2002-08-22 05:29:53 UTC Re: OK... Wall Wart Bad Idea for someone who would have to ask what size! Carol & Jerry Jankura 2002-08-22 05:36:44 UTC RE: [CAD_CAM_EDM_DRO] OK... Wall Wart Bad Idea for someone who would have to ask what size! Clinton Driggars 2002-08-22 08:13:41 UTC Re: [CAD_CAM_EDM_DRO] OK... Wall Wart Bad Idea for someone who would have to ask what size! ksprayberry428 2002-08-22 09:05:11 UTC Re: OK... Wall Wart Bad Idea for someone who would have to ask what size! ksprayberry428 2002-08-22 09:08:01 UTC Re: OK... Wall Wart Bad Idea for someone who would have to ask what size! Keith Bowers 2002-08-22 09:39:52 UTC Re: [CAD_CAM_EDM_DRO] Re: OK... Wall Wart Bad Idea for someone who would have to ask what size! cadcamcenter 2002-08-22 10:25:08 UTC Re: OK... Wall Wart Bad Idea for someone who would have to ask what size! Carol & Jerry Jankura 2002-08-22 13:17:30 UTC RE: [CAD_CAM_EDM_DRO] OK... Wall Wart Bad Idea for someone who would have to ask what size!