CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] VFD's - Variable Frequency Drive

Posted by Helen Fahy
on 2003-03-18 17:02:11 UTC
When I was first exposed to analog VFD drives ~15 years ago, the rule of thumb was 50% of rated speed or 30hz. I was told that this was to ensure proper cooling of the TEFC motor. These motors were on industrial equipment operated 24/7 in a wastewater treatment plant. I never did monitor the temperature, but I did not have any temperature related motor failures using 30hz minimum speed.



Joe Fahy
----- Original Message -----
From: mayfieldtm
To: CAD_CAM_EDM_DRO@yahoogroups.com
Sent: Tuesday, March 18, 2003 7:33 PM
Subject: [CAD_CAM_EDM_DRO] VFD's - Variable Frequency Drive



When I inquired with the Lathe Sales Person on the
Amperage Rating of my Motor. He said that I should
never run the Motor under 40Hz, in that it could
damage the Motor.

Is this true?

I mean I would expect that very slow or fast speeds
are not desirable, but, 40Hz is only 67% of normal.

(I was planning to use a range of about 20Hz to 90Hz.)
(3 times slower to 50% faster)

After all the glowing comments that I've read by "happy"
VFD users, now I have doubts about my purchase.

Any one have a VFD, and any comments?

Tom M.



Addresses:
FAQ: http://www.ktmarketing.com/faq.html
FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com

Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@..., timg@...
Moderator: pentam@... indigo_red@... [Moderators]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO

OFF Topic POSTS: General Machining
If you wish to post on unlimited OT subjects goto: aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if you have trouble.
http://www.metalworking.com/news_servers.html

http://groups.yahoo.com/group/jobshophomeshop I consider this to be a sister site to the CCED group, as many of the same members are there, for OT subjects, that are not allowed on the CCED list.

NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM. DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
bill
List Mom
List Owner



Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/



---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.462 / Virus Database: 261 - Release Date: 3/13/03


[Non-text portions of this message have been removed]

Discussion Thread

mayfieldtm 2003-03-18 16:33:46 UTC VFD's - Variable Frequency Drive dcdziner 2003-03-18 16:47:30 UTC Re: [CAD_CAM_EDM_DRO] VFD's - Variable Frequency Drive Helen Fahy 2003-03-18 17:02:11 UTC Re: [CAD_CAM_EDM_DRO] VFD's - Variable Frequency Drive Jon Elson 2003-03-18 22:24:16 UTC Re: [CAD_CAM_EDM_DRO] VFD's - Variable Frequency Drive