Re: [CAD_CAM_EDM_DRO] Re: Stepper motor voltage VS amps.
Posted by
Jon Elson
on 2003-05-19 22:18:20 UTC
turbulatordude wrote:
pulse frequency
modulation, but with fixed on or off time, the result is the same) is
used to regulate
current in the motor windings. The AVERAGE voltage across the winding
will work
out to about 2 volts in your case, but the full 40 volts is applied to
the winding during the
on time. So, the on time needs to be about 2/40 in this case, or 1/20th
of the time on,
19/20th of the time off. (There are numerous variations on this in how
the on/off
time is managed, or whether it uses time ratios of forward vs. reverse
current, with no
current recirculation.)
Jon
>In all chopper drives, some form of pulse width modulation (some use
>Am I correct in saying that you are describing something like a pulse
>width output ?
>
>and that even though it may be connected to 40 volts, the actual
>voltage reaching the motor will be 2 volts ?
>
>
pulse frequency
modulation, but with fixed on or off time, the result is the same) is
used to regulate
current in the motor windings. The AVERAGE voltage across the winding
will work
out to about 2 volts in your case, but the full 40 volts is applied to
the winding during the
on time. So, the on time needs to be about 2/40 in this case, or 1/20th
of the time on,
19/20th of the time off. (There are numerous variations on this in how
the on/off
time is managed, or whether it uses time ratios of forward vs. reverse
current, with no
current recirculation.)
Jon
Discussion Thread
sriddle68
2003-05-19 03:28:13 UTC
Stepper motor voltage VS amps.
fortino
2003-05-19 05:41:19 UTC
Re: [CAD_CAM_EDM_DRO] Stepper motor voltage VS amps.
Miroslav Pejic
2003-05-19 05:44:03 UTC
RE: [CAD_CAM_EDM_DRO] Stepper motor voltage VS amps.
Harvey White
2003-05-19 09:18:36 UTC
Re: [CAD_CAM_EDM_DRO] Stepper motor voltage VS amps.
Jon Elson
2003-05-19 11:09:35 UTC
Re: [CAD_CAM_EDM_DRO] Stepper motor voltage VS amps.
sriddle68
2003-05-19 12:48:31 UTC
Re: Stepper motor voltage VS amps.
turbulatordude
2003-05-19 14:29:24 UTC
Re: Stepper motor voltage VS amps.
Steven Ciciora
2003-05-19 14:35:16 UTC
Re: [CAD_CAM_EDM_DRO] Re: Stepper motor voltage VS amps.
Jon Elson
2003-05-19 14:52:50 UTC
Re: [CAD_CAM_EDM_DRO] Stepper motor voltage VS amps.
Harvey White
2003-05-19 19:36:11 UTC
Re: [CAD_CAM_EDM_DRO] Re: Stepper motor voltage VS amps.
turbulatordude
2003-05-19 19:44:19 UTC
Re: Stepper motor voltage VS amps.
Harvey White
2003-05-19 19:55:31 UTC
Re: [CAD_CAM_EDM_DRO] Re: Stepper motor voltage VS amps.
Jon Elson
2003-05-19 22:18:20 UTC
Re: [CAD_CAM_EDM_DRO] Re: Stepper motor voltage VS amps.
turbulatordude
2003-05-20 04:35:17 UTC
Re: Stepper motor voltage VS amps.