Question on VFD line rectors
Posted by
washcomp
on 2003-11-08 16:07:36 UTC
I'm planning on adding a VFD to my Bridgeport (varying the speed
from my CNC controller). They recommend the use of a line reactor
on both the input and the output sides.
Locally, I have 208V 3 phase A.C. 60Hz.
I have a 1.5 HP motor on my Bridgeport
I came across this and was wondering if it would be the proper one
my application:
http://cgi.ebay.com/ws/eBayISAPI.dll?
ViewItem&category=42881&item=2570523396
Thanks and regards,
Jeff
from my CNC controller). They recommend the use of a line reactor
on both the input and the output sides.
Locally, I have 208V 3 phase A.C. 60Hz.
I have a 1.5 HP motor on my Bridgeport
I came across this and was wondering if it would be the proper one
my application:
http://cgi.ebay.com/ws/eBayISAPI.dll?
ViewItem&category=42881&item=2570523396
Thanks and regards,
Jeff
Discussion Thread
washcomp
2003-11-08 16:07:36 UTC
Question on VFD line rectors
Jon Elson
2003-11-09 17:16:54 UTC
Re: [CAD_CAM_EDM_DRO] Question on VFD line rectors
Matt Shaver
2003-11-09 19:12:39 UTC
Re: [CAD_CAM_EDM_DRO] Question on VFD line rectors
anti_entropics
2003-11-09 22:07:22 UTC
Re: Question on VFD line rectors
washcomp
2003-11-10 21:05:57 UTC
Re: The Answers: Question on VFD line rectors