Re: ParPort output low - hi-Z or ground?
Posted by
caudlet
on 2004-04-08 05:50:11 UTC
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "ghidera2000"
<ghidera2000@y...> wrote:
As I have stated in the past there is value in learning. I found
the challenge of hooking up the mechanical components, wiring the
unit, building the controller and getting it all working with the
CAD, CAM and controller software configured and working to be a
sufficent challenge.
I like to see progress and perhaps I am impatient enough that I
don't want to work down at the component level unless absolutely
forced to do so. Even with buying my motor controllers, breakout
cards and controller software, it still took me almost a year of
weekends and spare time to complete my router/plasma table. I
learned a lot along the way without building all of it piece by
piece.
We will help you along with whatever you want to do. Post your
schematics and we will give you suggestions.
<ghidera2000@y...> wrote:
> --- In CAD_CAM_EDM_DRO@yahoogroups.com, "caudlet" <info@t...>wrote:
>kind
> I'm taking the LED power from a floppy connector so that the
> controller board and opto's are on completely different power
> supplies.
>
> > I am an EE with enough experience and spare parts to build any
> > of IO interface I want. I bought a Campbell board.build <
>
> I hear ya! 8) I was (am) really tempted to buy a Xylotex board.
> parts/pcb costs alone is pretty close a complete board solution.
> Thing is, having a CNC controller is only 1/3 of the reason for
> building it myself. You see, my actual hobby is learning.
> Electronics, metalwork, woodwork, plastics etc are simply the
> vehicles that bring me more knowledge. I would actually rather
As I have stated in the past there is value in learning. I found
the challenge of hooking up the mechanical components, wiring the
unit, building the controller and getting it all working with the
CAD, CAM and controller software configured and working to be a
sufficent challenge.
I like to see progress and perhaps I am impatient enough that I
don't want to work down at the component level unless absolutely
forced to do so. Even with buying my motor controllers, breakout
cards and controller software, it still took me almost a year of
weekends and spare time to complete my router/plasma table. I
learned a lot along the way without building all of it piece by
piece.
We will help you along with whatever you want to do. Post your
schematics and we will give you suggestions.
Discussion Thread
ghidera2000
2004-04-07 10:56:29 UTC
ParPort output low - hi-Z or ground?
Roy J. Tellason
2004-04-07 13:11:56 UTC
Re: [CAD_CAM_EDM_DRO] ParPort output low - hi-Z or ground?
caudlet
2004-04-07 13:27:09 UTC
Re: ParPort output low - hi-Z or ground?
ibewgypsie
2004-04-07 13:36:59 UTC
Re: ParPort output low - hi-Z or ground?
ghidera2000
2004-04-07 19:45:40 UTC
Re: ParPort output low - hi-Z or ground?
JanRwl@A...
2004-04-07 21:02:58 UTC
Re: [CAD_CAM_EDM_DRO] ParPort output low - hi-Z or ground?
turbulatordude
2004-04-07 23:47:46 UTC
Re: ParPort output low - hi-Z or ground?
caudlet
2004-04-08 05:37:11 UTC
Re: ParPort output low - hi-Z or ground?
caudlet
2004-04-08 05:50:11 UTC
Re: ParPort output low - hi-Z or ground?
ghidera2000
2004-04-08 08:14:58 UTC
Re: ParPort output low - hi-Z or ground?
ghidera2000
2004-04-08 08:21:06 UTC
Re: ParPort output low - hi-Z or ground?
Jon Elson
2004-04-08 10:13:29 UTC
Re: [CAD_CAM_EDM_DRO] Re: ParPort output low - hi-Z or ground?
turbulatordude
2004-04-08 14:03:18 UTC
Re: ParPort output low - hi-Z or ground?
caudlet
2004-04-08 17:21:36 UTC
Re: ParPort output low - hi-Z or ground?
turbulatordude
2004-04-08 18:34:47 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
Roy J. Tellason
2004-04-08 19:13:14 UTC
Re: [CAD_CAM_EDM_DRO] Re: ParPort output low - hi-Z or ground? opto to parallel
afogassa
2004-04-08 20:34:24 UTC
Re: ParPort output low - hi-Z or ground?
Harvey White
2004-04-08 22:11:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: ParPort output low - hi-Z or ground?
JanRwl@A...
2004-04-08 22:44:11 UTC
Re: [CAD_CAM_EDM_DRO] Re: ParPort output low - hi-Z or ground? opto to parallel
turbulatordude
2004-04-08 22:46:19 UTC
Re: ParPort output low - hi-Z or ground? - file section
JanRwl@A...
2004-04-08 22:59:19 UTC
Re: [CAD_CAM_EDM_DRO] Re: ParPort output low - hi-Z or ground?
caudlet
2004-04-09 06:56:58 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
turbulatordude
2004-04-09 07:45:08 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
ghidera2000
2004-04-09 08:15:45 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
caudlet
2004-04-09 12:03:07 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
turbulatordude
2004-04-09 19:02:53 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel
ghidera2000
2004-04-09 19:15:30 UTC
Re: ParPort output low - hi-Z or ground? opto to parallel