Re: [CAD_CAM_EDM_DRO] Dead servo
Posted by
Jon Elson
on 2004-05-01 00:31:44 UTC
k8zre wrote:
totally unprotected against such shorts.
Jon
>Jon...Yup, that's a pretty serious burnout. And, the Gecko and Rutex drives are
>
>I checked for short to ground and as I manually turned the servo
>motor, one of the windings is shorted to ground!! (Nuts) Motor
>still runs on bench cw/ccw.
>
>Thanks for the suggestion on testing.
>
>
totally unprotected against such shorts.
Jon
Discussion Thread
k8zre
2004-04-30 20:08:18 UTC
Dead servo
Jon Elson
2004-05-01 00:31:44 UTC
Re: [CAD_CAM_EDM_DRO] Dead servo
Vladimir Huzevka RUTEX.COM
2004-05-07 06:39:02 UTC
Re: [CAD_CAM_EDM_DRO] Dead servo
Jon Elson
2004-05-07 09:17:27 UTC
Re: [CAD_CAM_EDM_DRO] Dead servo