Re: [CAD_CAM_EDM_DRO] No movement
Posted by
Jon Elson
on 2004-08-14 22:10:48 UTC
Gene wrote:
axis? It certainly should. Where are you getting the +5 from? Do you have
two parallel ports? Is it possible you have hooked the Gecko drives to the
wrong parallel port? Are these Gecko 201, 210, 320 or 340? It makes a
difference, as 210 and 340 drives can be set for common positive or
common negative. You probably want common positive, like the G201 and
320 always use.
Is the breakout board an active one (ie. it has chips on it)? If so, do you
have the power supply connected correctly for it?
The voltage on the step term should change when you jog, also.
Jon
>I am still trying to get my machine to move. I can get EMC to home byDoes the dir voltage change when you change the jog direction for that
>tripping the home switch's by hand, The letters turn green and start
>counting when I push Jog, but no movement of the motors. The I/O show
>script shows the pins changing colors and reacting to the jog commands.
>On the geckos I get 1.56 volts between the +5 term. and the step term,
>and 4.65 volts between the +5 term. and the dir term.
>
axis? It certainly should. Where are you getting the +5 from? Do you have
two parallel ports? Is it possible you have hooked the Gecko drives to the
wrong parallel port? Are these Gecko 201, 210, 320 or 340? It makes a
difference, as 210 and 340 drives can be set for common positive or
common negative. You probably want common positive, like the G201 and
320 always use.
Is the breakout board an active one (ie. it has chips on it)? If so, do you
have the power supply connected correctly for it?
The voltage on the step term should change when you jog, also.
Jon
Discussion Thread
Gene
2004-08-14 15:41:49 UTC
No movement
Roy J. Tellason
2004-08-14 15:56:06 UTC
Re: [CAD_CAM_EDM_DRO] No movement
Jon Elson
2004-08-14 22:10:48 UTC
Re: [CAD_CAM_EDM_DRO] No movement
Jon Elson
2004-08-14 22:16:44 UTC
Re: [CAD_CAM_EDM_DRO] No movement
Gene
2004-08-15 16:06:20 UTC
No movement
Jon Elson
2004-08-15 18:21:59 UTC
Re: [CAD_CAM_EDM_DRO] No movement