Re: Bridgeport Interact 412/Heidenhain TNC 151 HELP
Posted by
jhtkcarn
on 2004-08-20 21:07:47 UTC
you are correct program must start at 0 and in lines 1,2,3,4,5,6
or you get what you are getting have you looked at the program
before you up load to conrol. your post maybe putting invalad data
into program. 151 control will not accept comments in program
there is a program called renumber that will fixed programs that are
not numbered correctly I have it but not at home. i can get it on
monday if you need it what program do you use to transfer from pc to
control. if you use blockwise which is drip feed with out actually
loading into machine memory it does not care if numbers are correct
only that progam starts at line 0 if you need any more help just
email me jhtkcarn@...
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Lawrence" <monkeyrt@h...>
wrote:
or you get what you are getting have you looked at the program
before you up load to conrol. your post maybe putting invalad data
into program. 151 control will not accept comments in program
there is a program called renumber that will fixed programs that are
not numbered correctly I have it but not at home. i can get it on
monday if you need it what program do you use to transfer from pc to
control. if you use blockwise which is drip feed with out actually
loading into machine memory it does not care if numbers are correct
only that progam starts at line 0 if you need any more help just
email me jhtkcarn@...
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Lawrence" <monkeyrt@h...>
wrote:
> Hi,working on
>
> I am a new student learning CNC programming/machining. I am
> a Bridgeport Interact 412 VMC with the Heidenhain TNC 151controller,
> and using MasterCam Version 8. So far everything is going well,except
> for one problem.mode is
>
> The manual says that the Heidenhain has two running modes. One
> "Program run 1-block," (top row, middle button) meaning thatit
> it will
> run one block of code at one time. In order to advance to the next
> line of code, I will have to push the "cycle start" button.
> This I
> understand.
>
> The other mode is "Program run-full sequence," (top row, 2nd
> button
> from right) meaning that it "should" run the complete file by
> pushing
> the "cycle start" button only once.
>
> My problem is that when I upload the file into the Heidenhain
> controller, and then go to the "Program run-full sequence"
> mode, I
> still have to manually push the "cycle start" button each
> time so it
> can go to the next line of code. According to the manual, it is
> supposed to run though all the lines automatically. It seems like
> is running in the "run 1-block" mode all the time.gap,
>
> I have also noticed that when the file is uploaded into the
> controller, the program lines start at #0 (Begin PGM 100), and then
> there is a big gap and the program begins much later (around line
> 70-or so depending on the program). I tried to delete the extra
> but the controller will not allow me to do so.must be
>
> If I were to go to "Program-full sequence" and upload
> directly from
> the computer, the machine will run perfectly, but the down side is
> that the file is not stored into the Heidenhain controller. It
> uploaded every time. In this mode, I also notice that the codestarts
> at line 100 (instead of 0) and it goes straight through to the end
> (without any gaps). The machine works perfectly this way.
>
> I was thinking maybe I am using the wrong post-processor? Or there
> might be some kind of setting on the Heidenhain that I don't know
> about?
>
> I do also have a picture of the Heidenhain controller buttons
> available.
>
> I really appreciate any help you can provide.
>
> Thank you in advance!
> Larry
Discussion Thread
Lawrence
2004-08-20 20:00:01 UTC
Bridgeport Interact 412/Heidenhain TNC 151 HELP
jhtkcarn
2004-08-20 21:07:47 UTC
Re: Bridgeport Interact 412/Heidenhain TNC 151 HELP
TomP
2004-08-21 08:04:17 UTC
Re: [CAD_CAM_EDM_DRO] Bridgeport Interact 412/Heidenhain TNC 151 HELP
Larry .
2004-08-24 15:20:26 UTC
Re: [CAD_CAM_EDM_DRO] Bridgeport Interact 412/Heidenhain TNC 151 HELP