Re: [CAD_CAM_EDM_DRO] Boss 5 retrofitting project
Posted by
Jon Elson
on 2004-08-23 20:45:35 UTC
rocketscientistnate wrote:
So, no helical interpolation, or 3 axis linear moves. If you want to do
contouring, this would be a limitation, as you couldn't move Z while
X and Y were moving simultaneously. So, you could only contour on
a strict X-Y axis grid, with all passes across the work being aligned to
either X or Y.
Jon
>\ By the way,2.5 axis means that coordinated moves in only 2 axes are supported.
>I've seen things that say 2.5 axes, what is half an axis anyway?
>
So, no helical interpolation, or 3 axis linear moves. If you want to do
contouring, this would be a limitation, as you couldn't move Z while
X and Y were moving simultaneously. So, you could only contour on
a strict X-Y axis grid, with all passes across the work being aligned to
either X or Y.
Jon