Re: step dir inputs on Gecko Bridgeport saga
Posted by
Keith Clark
on 2004-09-07 05:19:02 UTC
Andy, It worked nicely when connected to ground but without the
resistor.
Keith Clark
--- In CAD_CAM_EDM_DRO@yahoogroups.com, Andy Wander <awander@v...>
wrote:
resistor.
Keith Clark
--- In CAD_CAM_EDM_DRO@yahoogroups.com, Andy Wander <awander@v...>
wrote:
> But, unless he switches it to ground, the optocoupler will neverlight(+5V
> is the "common")Bridgeport saga
>
> Andy
>
> -----Original Message-----
> From: Jon Elson
> To: CAD_CAM_EDM_DRO@yahoogroups.com
> Sent: 9/7/2004 1:10 AM
> Subject: Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko
>the +5
> JanRwl@A... wrote:
>
> >In a message dated 9/6/2004 8:07:29 PM Central Standard Time,
> >mail@t... writes:
> >Any suggestions?
> >Yes. The "logic level" must go "hard" to ground. Just opening
> VDCgate
> >source doesn't do it, as the "internal stuff" in the IC where the
> involvedideally).
> >connects will often "pull up" the input line (though not
> >and
> >Suggest you connect the +5 to this DIR input via a 1K resistor,
> then thatthis a
> >same point to GND via the switch. The switch, then, will make
> "hardthe
> >LOW" when closed, and a "pulled-up +ve" when open.
> >
> >
> No, not needed with the Gecko drives. They have optocouplers of
> 2531 varietywill
> that require about 15 mA to turn on. So, opening the connection
> guaranteereach it
> the LED is off. What you say is totally correct for a logic gate,
> especially a
> CMOS gate, which can stay charged for days.
>
> Jon
>
>
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
>
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@a...,
> timg@k...
> Moderator: pentam@c... indigo_red@q... davemucha@j...
> [Moderators]
> URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto:
> aol://5863:126/rec.crafts.metalworking or go thru Google.com to
> if you have trouble.be a
> http://www.metalworking.com/news_servers.html
>
> http://groups.yahoo.com/group/jobshophomeshop I consider this to
> sister site to the CCED group, as many of the same members arethere,
> for OT subjects, that are not allowed on the CCED list.THEM.
>
> NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING
> DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
> bill
> List Mom
> List Owner
>
>
> Yahoo! Groups Links
Discussion Thread
Keith Clark
2004-09-06 17:40:00 UTC
step dir inputs on Gecko Bridgeport saga
Stephen Wille Padnos
2004-09-06 18:05:48 UTC
Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga
james_cullins@s...
2004-09-06 18:22:10 UTC
Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga
JanRwl@A...
2004-09-06 21:04:09 UTC
Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga
Keith Clark
2004-09-06 21:25:39 UTC
Re: step dir inputs on Gecko Bridgeport saga
Jon Elson
2004-09-06 22:14:28 UTC
Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga
Andy Wander
2004-09-07 05:15:43 UTC
RE: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga
Keith Clark
2004-09-07 05:19:02 UTC
Re: step dir inputs on Gecko Bridgeport saga
james_cullins@s...
2004-09-07 05:29:20 UTC
Re: [CAD_CAM_EDM_DRO] Re: step dir inputs on Gecko Bridgeport saga
JanRwl@A...
2004-09-07 08:39:41 UTC
Re: [CAD_CAM_EDM_DRO] step dir inputs on Gecko Bridgeport saga