Variable frequency drive question
    Posted by
    
      Troy
    
  
  
    on 2004-11-19 18:57:22 UTC
  
  How does the voltage rating of a variable frequency drive work.  I 
wish to power the spindle of a 1hp brigeport mill and we have 240
three phase in the shop.
Can I run this from a drive (GE AF-300B)that is rated for 460max
voltage or do the voltages of the drive and the motor and the supply
need to match?
Thanks in advance
Troy
wish to power the spindle of a 1hp brigeport mill and we have 240
three phase in the shop.
Can I run this from a drive (GE AF-300B)that is rated for 460max
voltage or do the voltages of the drive and the motor and the supply
need to match?
Thanks in advance
Troy
Discussion Thread
  
    Troy
  
2004-11-19 18:57:22 UTC
  Variable frequency drive question
  
    Ron Kline
  
2004-11-19 19:22:44 UTC
  Re: [CAD_CAM_EDM_DRO] Variable frequency drive question
  
    Hugh Prescott
  
2004-11-19 19:24:37 UTC
  Re: [CAD_CAM_EDM_DRO] Variable frequency drive question
  
    Jon Elson
  
2004-11-19 19:34:33 UTC
  Re: [CAD_CAM_EDM_DRO] Variable frequency drive question
  
    turbulatordude
  
2004-11-20 06:49:50 UTC
  Re: Variable frequency drive question
  
    Hugh Prescott
  
2004-11-21 10:51:36 UTC
  Re: [CAD_CAM_EDM_DRO] Re: Variable frequency drive question
  
    turbulatordude
  
2004-11-21 14:08:08 UTC
  Re: Variable frequency drive question