CAD CAM EDM DRO - Yahoo Group Archive

Re: Opto 22 Lags

on 2005-03-15 10:13:57 UTC
Opto 22 relays come in different flavors for AC, DC
and different voltages. Is it possible that the
voltage at the control jack of your plasma cutter
is low voltage DC and you are trying to control it
with an AC Opto 22 module? The AC modules have a
Triac in them that will stay on forever as long
as the load current is sufficient to sustain them.
With a low current DC load they may eventually drift
to the off condition.

Regards,
Steve Stallings
www.pmdx.com

--- In CAD_CAM_EDM_DRO@yahoogroups.com, "bertmantx" <bertmantx@y...>
wrote:
>
> Can anyone tell me why my opto 22 relays are so slow to turn off??
> torch continues to arc 2-5secs. after signal quits.
> I'm hooking port pin 9 to "+" and gnd pin 18 to "-" and torch to
> contact symbol.

Discussion Thread

bertmantx 2005-03-15 10:05:15 UTC Opto 22 Lags Steve Stallings 2005-03-15 10:13:57 UTC Re: Opto 22 Lags bertmantx 2005-03-15 13:20:33 UTC Re: Opto 22 Lags Steve Stallings 2005-03-15 13:34:50 UTC Re: Opto 22 Lags