Re: Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Posted by
Jim Dubois
on 2006-08-30 10:15:01 UTC
Dan,
thanks for the immediate response, long time no talk...like about 12
years...in any event, I miss stated the grounding piece. What I
intended to say is the 65 vdc, the 5 vdc, as well as the parrallel
port and AC grounds are all common. I did not intend to say I had
grounded the +5vdc line.....it is just as you suggested, daisy
chained Gecko "commons" to the +5vdc supply.
So, do you have experience successfully driving the Gecko's directly
off a parrallel port? or do i need an interface board?
best regards
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Dan Mauch" <dmauch@...>
wrote:
thanks for the immediate response, long time no talk...like about 12
years...in any event, I miss stated the grounding piece. What I
intended to say is the 65 vdc, the 5 vdc, as well as the parrallel
port and AC grounds are all common. I did not intend to say I had
grounded the +5vdc line.....it is just as you suggested, daisy
chained Gecko "commons" to the +5vdc supply.
So, do you have experience successfully driving the Gecko's directly
off a parrallel port? or do i need an interface board?
best regards
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Dan Mauch" <dmauch@...>
wrote:
>chained wired to
> The +5 must not be tied to ground . It should only be daisy
> the +5 common terminals of each drive. Nowhere else.directly with
> Dan Mauch
> low cost stepper and servo motors.
> cases for Gecko drives
> kits and assembled 3-4 axis drives
> www.camtronics-cnc.com
> www.seanet.com/~dmauch
> ----- Original Message -----
> From: "Jim Dubois" <jdubois@...>
> To: <CAD_CAM_EDM_DRO@yahoogroups.com>
> Sent: Wednesday, August 30, 2006 7:51 AM
> Subject: [CAD_CAM_EDM_DRO] Gecko 201 drives, can I drive them
> a Parallel port on my computerhave
>
>
> >I have a problem with Gecko drives not working, I am assuming I
> > done something stupid or have overlooked something....or will aPC
> > parallel port not actually "sink" the required 16ma? I have usedterminal
> > the parallel port for control of many drivers, but for what ever
> > reason the Geckos are not working. This is my first effort with
> > Gekos....
> >
> > I have replaced a set of IMS drivers on a formerly functioning
> > controller with new out of the box Gecko 201 drivers. I have +65
> > vdc, tied to a chassis ground, I have +5vdc for the common
> > on the drives, also tied to chassis ground. The parallel port,also
> > grounded properly, is communicating with the controller as I canconnection
> > turn on and turn off the aux devices, ie spindle, coolant and the
> > like. The power light is "on" on the drives, the motors "lock".
> > Current setting on the drives is at default, 7 amps. No
> > to the "disable" connection. There are no limit switches or otherhave
> > complexity...just a 3 axis controller with 2 aux's and the aux's
> > work.
> >
> > I have checked out the controller with a different computer, no
> > change. I have verified the +5vdc to common stays steady. I
> > not been able to verify the TTL signals, no scope or logic tracethink it
> > tools in house. But, it worked with the IMS...so...I would
> > would work with Gecko.....the
> >
> > any thoughts? do I need a parallel port interface card to drive
> > Gecko's?wanliker@...,
> >
> >
> >
> >
> >
> >
> > Addresses:
> > FAQ: http://www.ktmarketing.com/faq.html
> > FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> > Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
> >
> > Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> > Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> > List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com,
> > timg@...reach it
> > Moderator: pentam@... indigo_red@... davemucha@...
> > [Moderators]
> > URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> >
> > OFF Topic POSTS: General Machining
> > If you wish to post on unlimited OT subjects goto:
> > aol://5863:126/rec.crafts.metalworking or go thru Google.com to
> > if you have trouble.to be a
> > http://www.metalworking.com/news_servers.html
> >
> > http://groups.yahoo.com/group/jobshophomeshop I consider this
> > sister site to the CCED group, as many of the same members arethere, for
> > OT subjects, that are not allowed on the CCED list.POSTING THEM.
> >
> > NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY
> > DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
> > bill
> > List Mom
> > List Owner
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
> >
>
Discussion Thread
Jim Dubois
2006-08-30 07:56:24 UTC
Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Dan Mauch
2006-08-30 09:32:25 UTC
Re: [CAD_CAM_EDM_DRO] Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Robert Colin Campbell
2006-08-30 09:33:33 UTC
Re: [CAD_CAM_EDM_DRO] Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Jim Dubois
2006-08-30 09:51:55 UTC
Re: Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Jim Dubois
2006-08-30 10:15:01 UTC
Re: Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Dan Mauch
2006-08-30 12:22:40 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko 201 drives, can I drive them directly with a Parallel port on my computer
Arturo E. Duncan
2006-08-31 19:58:18 UTC
Re: Gecko 201 drives, can I drive them directly with a Parallel port on my computer