Jon,

I'm running 3 phase into the inverter.

Looking in Newark, I found the types of filters you referenced at C&H
but in 3 phase. A Schaffner low current model at 10 amps is $88.
Yikes!
Well, mounting the inverter on the wall has all but eliminated the
problem. That is, reduced it to a level I can live with for now.
I think I'll need to evaluate what further projects I'm going to be
putting inverters on. For just under $300, I could get a unit that would
cover everything I might ever try to run in my shop, but I'd have to
rewire things to get all lines feeding the inverters to the filter in as
short a distance as possible without crossing something else.

Thanks much for your help!

Jon A











> Jon Anderson wrote:
>
> > Jon,
> >
> > What exactly are these filters called? I'm looking through a Graingers
> > catalog index, and not coming up with anything.
>
> Not surprising. I wouldn't look in Grainger's for electronic components,
> although they might have them.
>
> Here's 2 from the C & H sales catalog. These are single phase
> filters, good for 120 or 240 V line-line. A 6 Amp unit, looks exactly
> like mine, is stock # PF9002, at $4.95. They also have a 20 A unit,
> PF9901, for $7.75. The 6 A one looks like it might be a better filter,
> if the current rating would be adequate for your use. This is from the
> fall 2000 catalog. Their phone # is 800-325-9465.
>
> Jon
>
> Welcome to CAD_CAM_EDM_DRO@...,an unmoderated list for the discussion of shop built systems, for CAD, CAM, EDM, and DRO.
>
> Addresses:
> Post message: CAD_CAM_EDM_DRO@yahoogroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
> Moderator: jmelson@... timg@... [Moderator]
> URL to this page: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> bill,
> List Manager
>
> FAQ: http://www.ktmarketing.com/faq.html

Discussion Thread

Jon Anderson 2001-02-06 15:28:08 UTC Strange lost step problem, grounding related Jon Elson 2001-02-06 22:13:06 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related Jon Anderson 2001-02-07 08:59:22 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related Jon Elson 2001-02-07 09:23:23 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related Jon Anderson 2001-02-07 10:04:28 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related dougrasmussen@c... 2001-02-07 10:43:06 UTC Re: Strange lost step problem, grounding related Jon Elson 2001-02-07 13:28:13 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related dave engvall 2001-02-07 18:02:50 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related ballendo@y... 2001-02-07 18:14:35 UTC Re: Strange lost step problem, grounding related Jon Anderson 2001-02-07 18:17:33 UTC Re: [CAD_CAM_EDM_DRO] Strange lost step problem, grounding related dougrasmussen@c... 2001-02-07 19:34:19 UTC Re: Strange lost step problem, grounding related Jon Anderson 2001-02-07 20:02:26 UTC Re: [CAD_CAM_EDM_DRO] Re: Strange lost step problem, grounding related dave engvall 2001-02-07 21:06:40 UTC Re: [CAD_CAM_EDM_DRO] Re: Strange lost step problem, grounding related dave engvall 2001-02-07 21:09:27 UTC Re: [CAD_CAM_EDM_DRO] Re: Strange lost step problem, grounding related Mark Fraser 2001-02-08 05:36:02 UTC Re: Strange lost step problem, grounding related dougrasmussen@c... 2001-02-08 08:07:18 UTC Re: Strange lost step problem, grounding related Jon Anderson 2001-02-08 08:22:54 UTC Re: [CAD_CAM_EDM_DRO] Re: Strange lost step problem, grounding related dave engvall 2001-02-08 09:42:10 UTC Re: [CAD_CAM_EDM_DRO] Re: Strange lost step problem, grounding related