Hi,

The motor will be dissipating twice heat it should for very little
gain in holding torque, about 30 to 40 percent. There will be no
improvement at higher speeds at all compared to 0.5 amps. That 1 amp
current in half winding will give twice the power at higer speeds
compared to full winding.

Mariss

> Only if the resistance stays constant, which it doesn't - it doubles
> when you go from half coil to full. Another way to look at it - you
> put the same current in with twice the voltage, so the power
doubles.
>
> Chris
>
> --
> Christopher C. Stratton, stratton@m...
> Instrument Maker, Horn Player & Engineer
> 22 Adrian Street, Somerville, MA 02143
> http://www.mdc.net/~stratton
> NEW PHONE NUMBER: (617) 628-1062 home, 253-2606 MIT

Discussion Thread

rsidor@t... 2001-04-26 04:49:25 UTC stepper current mariss92705@y... 2001-04-26 09:22:54 UTC Re: stepper current Alan Marconett KM6VV 2001-04-26 10:37:20 UTC Re: [CAD_CAM_EDM_DRO] stepper current rsidor@t... 2001-04-26 11:22:01 UTC stepper current JanRwl@A... 2001-04-26 21:54:13 UTC Re: [CAD_CAM_EDM_DRO] stepper current rsidor@t... 2001-04-27 05:12:52 UTC Re: stepper current JanRwl@A... 2001-04-27 20:07:59 UTC Re: [CAD_CAM_EDM_DRO] Re: stepper current Carol & Jerry Jankura 2001-04-28 05:11:50 UTC RE: [CAD_CAM_EDM_DRO] Re: stepper current stratton@m... 2001-04-28 10:50:49 UTC Re: [CAD_CAM_EDM_DRO] Re: stepper current mariss92705@y... 2001-04-28 12:52:44 UTC Re: stepper current JanRwl@A... 2001-04-28 23:09:02 UTC Re: [CAD_CAM_EDM_DRO] Re: stepper current rsidor@t... 2001-04-29 07:14:34 UTC stepper current