RE: [CAD_CAM_EDM_DRO] BDI / Gecko 201 settings?
Posted by
Tim Goldstein
on 2001-07-20 20:31:47 UTC
You do not need to do anything with the MIN & MAX_OUTPUT values. They are
for servos with a Servo to GO card.
Set the INPUT_SCALE, OUTPUT_SCALE, and max rate and adjust the PERIOD
setting if using freqmod and you should be working. You may need to alter
some of the polarity settings. I am on the road so I don't have an EMC ini
file to refer to, but much of the per axis stuff is not for step and
direction output.
Tim
[Denver, CO]
for servos with a Servo to GO card.
Set the INPUT_SCALE, OUTPUT_SCALE, and max rate and adjust the PERIOD
setting if using freqmod and you should be working. You may need to alter
some of the polarity settings. I am on the road so I don't have an EMC ini
file to refer to, but much of the per axis stuff is not for step and
direction output.
Tim
[Denver, CO]
> Hello Group,
>
> Can some one point me to information about any special settings in
> EMC .ini files that need to be configured for interfacing to Gecko
> 201(A) drives? I think the MIN_OUTPUT, and MAX_OUTPUT settings refer
> to voltages? to the drives, so looking for this setting. I hope to
> move motors tonight when I finish the interface cable from computer
> to power box.
>
> Thank you,
> Allan
Discussion Thread
allan_r9@h...
2001-07-19 08:06:40 UTC
BDI / Gecko 201 settings?
Ray
2001-07-19 20:19:54 UTC
Re: BDI / Gecko 201 settings?
Tim Goldstein
2001-07-20 20:31:47 UTC
RE: [CAD_CAM_EDM_DRO] BDI / Gecko 201 settings?