Looking for assistance in connecting COMPUMOTOR DB DRIVE
Posted by
glee@i...
on 2002-01-14 16:04:35 UTC
I have 2 COMPUMOTOR DB DRIVE units which I would like to make use of.
I am trying to identify the functions of the wires that connect to these
units.
I would appreciate any feedback or links to web site as you may have.....
Also, any comments from anyone who has actually used these drives woudl be
welcome.
-Eric Mack
================================================================================
Pinouts for COMPUMOTOR DB DRIVE
On the LEFT side of the controller is an 8 position screw terminal which
looks like the power and motor side. It is labelled as follows:
B+ To Motor
B - To Motor
A + To Motor
A - To Motor
- 12-48V DC IN
+ 12-48V DC IN
CURRENT (No idea what this is for. Is this also tied to the DC
Supply voltage?
LOGIC GROUND (Do I just tie this to the PC Controller Ground and/or
to chassis ground?)
On the RIGHT side of the controller is an 8 Position screw terminal which
looks like the controller side. It is labelled as follows:
LOGIC GROUND (Do I just tie this to the PC Controller Ground and/or
to chassis ground?)
RES SEL A (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
RES SEL B (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
RES SEL C (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
DIR - (I assume that this goes to the direction pin on
the controller?)
DIR + (I assume that this goes to the direction pin on
the controller?)
STEP - (I assume that this goes to the step pin on the
controller?)
STEP + (I assume that this goes to the step pin on the
controller?)
I am trying to identify the functions of the wires that connect to these
units.
I would appreciate any feedback or links to web site as you may have.....
Also, any comments from anyone who has actually used these drives woudl be
welcome.
-Eric Mack
================================================================================
Pinouts for COMPUMOTOR DB DRIVE
On the LEFT side of the controller is an 8 position screw terminal which
looks like the power and motor side. It is labelled as follows:
B+ To Motor
B - To Motor
A + To Motor
A - To Motor
- 12-48V DC IN
+ 12-48V DC IN
CURRENT (No idea what this is for. Is this also tied to the DC
Supply voltage?
LOGIC GROUND (Do I just tie this to the PC Controller Ground and/or
to chassis ground?)
On the RIGHT side of the controller is an 8 Position screw terminal which
looks like the controller side. It is labelled as follows:
LOGIC GROUND (Do I just tie this to the PC Controller Ground and/or
to chassis ground?)
RES SEL A (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
RES SEL B (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
RES SEL C (No idea what this is but "A" is jumpered to "B" and
"C" Is not connected)
DIR - (I assume that this goes to the direction pin on
the controller?)
DIR + (I assume that this goes to the direction pin on
the controller?)
STEP - (I assume that this goes to the step pin on the
controller?)
STEP + (I assume that this goes to the step pin on the
controller?)
Discussion Thread
glee@i...
2002-01-14 16:04:35 UTC
Looking for assistance in connecting COMPUMOTOR DB DRIVE
Paul D. Fincato
2002-01-14 18:08:52 UTC
RE: [CAD_CAM_EDM_DRO] Looking for assistance in connecting COMPUMOTOR DB DRIVE
William Scalione
2002-01-15 05:07:47 UTC
Re: [CAD_CAM_EDM_DRO] Looking for assistance in connecting COMPUMOTOR DB DRIVE