RE: [CAD_CAM_EDM_DRO] Re: screening

Posted by JJ
on 2002-09-24 17:33:07 UTC
Put heatshrink on the cable.
Strip back a suitable amount of insulation, then trim the braid to about
1/2"
Strip a (separate) piece of wire long enough to go around the cable,
plus some to on itself. Wrap it around the cable just past the
insulation, and around the braid. Wrap the end of the wire to the other
part of the wire, forming a loop around the braid.
Fold the braid back around the wire and pull it away from the inner
wires.
Solder all the way around being careful not to melt the inner wires.
Aluminum foil might help here, but I haven't had a problem.
Trim the excess braid.
Pull the heat shrink down and heat shrink.

Another kind of anal thing I like to do is strip all the wires a little
longer than needed, pull them into their respective positions (red on 1,
blue on 2 or whatever), and trim them straight across . This keeps the
wires on the outside from banjo-stringing, and the inner ones from
pooching. Adjust accordingly for the position of the cable, left, right,
center, what have you.

That's what I would do.

Regards,
JJ

Be Kind, Be Careful, Be Yourself



> -----Original Message-----
> From: keongsan [mailto:keongsan@...]
> Sent: Tuesday, September 24, 2002 5:49 AM
> To: CAD_CAM_EDM_DRO@yahoogroups.com
> Subject: [CAD_CAM_EDM_DRO] Re: screening
>
>
> Jon Elson <elson@p...> wrote:
>
> > everything with interference. The braided wire shield is more
> durable
> > over the long term with much cable flexing
>
> With 3 2-wire braided cable for 3 axis driver, one end at DB25, other
> ends at step-dirn terminals of the 3 separate drives, to which end
> does one connect the earth shield - at the DB25 or at the earth of
> the individual drives?
>
> If at the DB25, we will have 3 separate braids coming out of the ends
> of the signal cable. How do we connect it (professionally looking) to
> the connector?
>
> Thanks
>
> Keongsan
>
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto:
> aol://5863:126/rec.crafts.metalworking or go thru Google.com
> to reach it if you have trouble.
> http://www.metalworking.com/news_servers.html
>
http://groups.yahoo.com/group/jobshophomeshop I consider this as a
sister site to the CCED group, as many of the same members are there,
for OT subjects, that are not allowed on the CCED list.

NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........

Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
Moderator: jmelson@... timg@... [Moderator]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
bill,
List Mom
List Owner



Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/

Discussion Thread

alex0young 2002-09-21 07:46:26 UTC screening JJ 2002-09-21 09:43:40 UTC RE: [CAD_CAM_EDM_DRO] screening Carol & Jerry Jankura 2002-09-21 09:56:36 UTC RE: [CAD_CAM_EDM_DRO] screening Jon Elson 2002-09-21 21:31:00 UTC Re: [CAD_CAM_EDM_DRO] screening w.higdon@a... 2002-09-22 08:58:25 UTC Re: [CAD_CAM_EDM_DRO] screening keongsan 2002-09-24 05:49:27 UTC Re: screening JJ 2002-09-24 17:33:07 UTC RE: [CAD_CAM_EDM_DRO] Re: screening