CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Step Motor wire max length?

Posted by JanRwl@A...
on 2003-01-22 16:48:09 UTC
In a message dated 1/22/2003 2:39:29 AM Central Standard Time,
builder4wd@... writes:


> Hi guys, I'm planning on soldering extension wires to my step motors.
> I want to add 5 feet per motor, and I was wondering if this would
> have any effect on performance? Thanks.
>

If large enough wire-gage. For Size-23, #18 AWG will probably be OK. For
some Size-34, #18 is marginal, others #16 is fine. And so on. DO the math!


[Non-text portions of this message have been removed]

Discussion Thread

builder4wd <builder4wd@y... 2003-01-22 00:38:59 UTC Step Motor wire max length? Peter Seddon 2003-01-22 03:07:46 UTC Re: [CAD_CAM_EDM_DRO] Step Motor wire max length? JanRwl@A... 2003-01-22 16:48:09 UTC Re: [CAD_CAM_EDM_DRO] Step Motor wire max length? JanRwl@A... 2003-01-22 16:51:24 UTC Re: [CAD_CAM_EDM_DRO] Step Motor wire max length? builder4wd <builder4wd@y... 2003-01-22 17:18:10 UTC Re: Step Motor wire max length?