Re: [CAD_CAM_EDM_DRO] CRAZY RELAY???
Posted by
Jon Elson
on 2003-03-19 21:10:20 UTC
ralaco wrote:
an electronic speed control? It probably draws short current pulses, and
the SSR shuts off any time there is no current flowing. You could probably
put a "snubber" across the router, to help this
situation. It would be a capacitor and a resistor in series. These would
probably have to have a pretty large rating in this case, possibly .47 uF
and a 100 Ohm, 50 Watt.
Jon
>I installed a solid state Relay to control my Router with Mach1.Solid state relays require somewhat resistive loads. Does your router have
>
>When I connect the Router to the Relay nothing happen, but if I
>install a bulb with the Router, everything is OK, the Router and the
>bulb turns ON and OFF.
>
>Is this OK and why?
>
>Is there a way, to make it works without a bulb
>
>
an electronic speed control? It probably draws short current pulses, and
the SSR shuts off any time there is no current flowing. You could probably
put a "snubber" across the router, to help this
situation. It would be a capacitor and a resistor in series. These would
probably have to have a pretty large rating in this case, possibly .47 uF
and a 100 Ohm, 50 Watt.