Re: [CAD_CAM_EDM_DRO] Power Supply for Servo System (Hot Supply using Variac)
Posted by
wanliker@a...
on 2003-07-29 19:07:33 UTC
In a message dated 7/29/2003 7:59:14 PM Mountain Daylight Time,
engineer@... writes:
When you use a variac you have no line isolation, and if any thing goes wrong
you can be killed quite quickly.
If the neutral wire to the variac breaks, the entire transformer element goes
to line potentional, and it hurts, ask me how I know.......
If you insist on a variac, then put a isolations transformer in front of it.
bill
[Non-text portions of this message have been removed]
engineer@... writes:
> The only thing I thought of was no isolation but what is that buyingA good chance to make your wife a widow, and your children have no father.
> me?
>
>
When you use a variac you have no line isolation, and if any thing goes wrong
you can be killed quite quickly.
If the neutral wire to the variac breaks, the entire transformer element goes
to line potentional, and it hurts, ask me how I know.......
If you insist on a variac, then put a isolations transformer in front of it.
bill
[Non-text portions of this message have been removed]
Discussion Thread
autom8_it
2003-07-29 18:58:41 UTC
Power Supply for Servo System (Hot Supply using Variac)
wanliker@a...
2003-07-29 19:07:33 UTC
Re: [CAD_CAM_EDM_DRO] Power Supply for Servo System (Hot Supply using Variac)
dougfennell2000
2003-07-29 20:07:02 UTC
Re: Power Supply for Servo System (Hot Supply using Variac)
caudlet
2003-07-29 21:51:30 UTC
Re: Power Supply for Servo System (Hot Supply using Variac)
Jon Elson
2003-07-29 22:44:44 UTC
Re: [CAD_CAM_EDM_DRO] Power Supply for Servo System (Hot Supply using Variac)