220 Voltage To Feed Machine Motor and CNC Drives
Posted by
brink905
on 2004-01-20 17:21:42 UTC
I've got a Bridgeport machine with a 3 hp motor which is three phase
that I am going run with 220 single phase thru a Hitachi SJ100
inverter. The inverter will convert single phase power to three
phase.
Question that I have can I also use the same 220 single phase line
to feed a 220 power supply that would be used for running Rutex
drivers for the servo motors? Or would it be better to have two
different 220 lines on separate breakers?
Thanks for any information provided,
Dave Brinkman
Yankton, SD
that I am going run with 220 single phase thru a Hitachi SJ100
inverter. The inverter will convert single phase power to three
phase.
Question that I have can I also use the same 220 single phase line
to feed a 220 power supply that would be used for running Rutex
drivers for the servo motors? Or would it be better to have two
different 220 lines on separate breakers?
Thanks for any information provided,
Dave Brinkman
Yankton, SD
Discussion Thread
brink905
2004-01-20 17:21:42 UTC
220 Voltage To Feed Machine Motor and CNC Drives
Jon Elson
2004-01-20 22:07:21 UTC
Re: [CAD_CAM_EDM_DRO] 220 Voltage To Feed Machine Motor and CNC Drives
Peter Renolds
2004-01-21 07:35:29 UTC
Re: [CAD_CAM_EDM_DRO] 220 Voltage To Feed Machine Motor and CNC Drives
Jon Elson
2004-01-21 10:18:07 UTC
Re: [CAD_CAM_EDM_DRO] 220 Voltage To Feed Machine Motor and CNC Drives
Peter Renolds
2004-01-21 12:51:17 UTC
Re: [CAD_CAM_EDM_DRO] 220 Voltage To Feed Machine Motor and CNC Drives
Gregory Kamysz
2004-01-21 18:02:32 UTC
Looking for a link
brink905
2004-01-21 18:31:38 UTC
Re: Looking for a link
brink905
2004-01-21 18:37:57 UTC
Re: 220 Voltage To Feed Machine Motor and CNC Drives
deanc500
2004-01-21 19:59:34 UTC
Re: Looking for a link
Gregory Kamysz
2004-01-21 20:17:51 UTC
Re: [CAD_CAM_EDM_DRO] Re: Looking for a link