Re: Bridgeport Stepper Voltage/Current?
Posted by
barker806
on 2004-03-12 09:32:02 UTC
> Anyway, what voltage do the stepper motors on the Brideports run?I
> intend to remove all of the drives and supplies and replacing themsupply
> with Gecko 201s for now. I was planning on building a new DC
> out of what is left in the box, but wasn't sure what to build itto.
> Obviously something less than the 80V the Geckos want to see. TheI have done 3 of them with g201's and about 76volts is the best, you
> electrical cabinet now only has test points for +/-5V and +/-12V,
> which I assume are logic leveland not the actual drive voltage.
will get about 100 IPM (I got 123) and they work great!! You are
going to want to put the motors in series on the windings.
Good luck
Brian
PS look out what you cut with a "Hack" saw...
Discussion Thread
Kevin R. Walsh
2004-03-12 09:26:17 UTC
Bridgeport Stepper Voltage/Current?
barker806
2004-03-12 09:32:02 UTC
Re: Bridgeport Stepper Voltage/Current?
Jon Elson
2004-03-12 10:41:59 UTC
Re: [CAD_CAM_EDM_DRO] Bridgeport Stepper Voltage/Current?
Les Newell
2004-03-13 03:56:21 UTC
Re: [CAD_CAM_EDM_DRO] Bridgeport Stepper Voltage/Current?
Tim Leech
2004-03-13 05:27:11 UTC
Re: Bridgeport Stepper Voltage/Current?