Re: Answer about how to set up VFD for braking resistor

Posted by washcomp
on 2005-01-27 14:21:35 UTC
I have an Omron/Yaskawa G5+ VFD and the question was what settings
should be changed in order properly utilize a breaking resistor

According to Omron and Yaskawa tech supports (called both<G>):

Use ramp to stop which will automaticly kick in the resistor if
required

Change parameter L3-04 to "0" which has to do with anti-stalling on
deceleration

Change deceleration parameter C-102 to decrease time it takes to stop

That seems to be about all there is to it.

Thanks for the help and hope someone else can use this in the future,

Jeff

Discussion Thread

washcomp 2005-01-26 18:56:19 UTC Question about how to set up VFD for braking resistor cnc_4_me 2005-01-26 19:07:00 UTC Re: Question about how to set up VFD for braking resistor washcomp 2005-01-26 19:47:58 UTC Re: Question about how to set up VFD for braking resistor Jon Elson 2005-01-26 22:20:36 UTC Re: [CAD_CAM_EDM_DRO] Re: Question about how to set up VFD for braking resistor washcomp 2005-01-27 04:59:32 UTC Re: Question about how to set up VFD for braking resistor Jon Elson 2005-01-27 10:31:55 UTC Re: [CAD_CAM_EDM_DRO] Re: Question about how to set up VFD for braking resistor washcomp 2005-01-27 11:55:22 UTC Re: Question about how to set up VFD for braking resistor washcomp 2005-01-27 14:21:35 UTC Re: Answer about how to set up VFD for braking resistor Jon Elson 2005-01-27 21:25:02 UTC Re: [CAD_CAM_EDM_DRO] Re: Question about how to set up VFD for braking resistor