David Howland wrote:
>
............
> A car alternator connected to an old
> washing machine 120 VAC Motor, can produce much more than 12 VDC after you
> cluge up a simple adjustable regulator circuit and the current output will
> be quite serious. In other words, in a similar package as a phase converter,
> one could have a very high output DC power supply. Such a silly idea may be
> reasonable for anyone with an old AC motor kicking around. Car alternators
> don't cost much. The regulator circuit isn't bad.
>

Be carefull here- there is no free lunch. If you just turn the
alternator with a washing machine motor, which are usually about 1/3 hp,
you wont get out of the alternator more than 1/3 hp, or 1/3*746 watts=
248 watts, actually, quite a bit less than this because of friction and
resistance. At best this could supply about 20 amps, but only at 12vdc.

If you tried to get you big spike load out of it it would just stall, or
maybe even kick the drive belt off. A big flywheel might help.

It would likely be a lot simpler to just get a power supply big enough
to do the job!

ron

Discussion Thread

Mariss Freimanis 2000-06-16 09:24:06 UTC Just an idea David Howland 2000-06-16 11:18:43 UTC RE: [CAD_CAM_EDM_DRO] Just an idea Jon Elson 2000-06-16 11:58:01 UTC Re: [CAD_CAM_EDM_DRO] Just an idea Carlos Guillermo 2000-06-16 12:18:31 UTC RE: [CAD_CAM_EDM_DRO] Just an idea Mariss Freimanis 2000-06-16 12:57:17 UTC Re: Just an idea Ron Ginger 2000-06-16 13:17:36 UTC Re: [CAD_CAM_EDM_DRO] Just an idea Doug Harrison 2000-06-16 15:08:55 UTC Re: [CAD_CAM_EDM_DRO] Just an idea Mariss Freimanis 2000-06-16 15:42:39 UTC Re: Just an idea