CAD CAM EDM DRO - Yahoo Group Archive

ReW.E.T.: [CAD_CAM_EDM_DRO] Re: Z-Axis Drive - - Tips and Suggestions

Posted by wthomas@g...
on 2005-09-03 18:28:25 UTC
Hi all:
What about the torque ratings on the power feeds for
Bridgeport and similar turret mills. These are rated from 100 lbs.
in. for continous torque up to 200 lbs. in. peak torque. This is for
the horz.axies usually with .200"/ turn (5 pitch) with a feed rate
of 0.1 to 50 in./min and a rapid of up to 80 in./min. The vertical
feed is only .100"/ turn (10 pitch) with a feed rate of 25 in./min.
and a rapid of up to 40 in./min.. The less expensive drives
feed only 0 to 25 in./min. with a 150 lbs. in torque. The standard
Bridgeport electronic feed is rated a 115 in. lbs at 35 in./min.
I hopes this helps you!
GOD'S BLESSINGS
Bill

Discussion Thread

mayfieldtm 2005-09-01 07:21:40 UTC Z-Axis Drive - - Tips and Suggestions turbulatordude 2005-09-01 09:50:40 UTC Re: Z-Axis Drive - - Tips and Suggestions mayfieldtm 2005-09-01 15:32:28 UTC Re: Z-Axis Drive - - Tips and Suggestions dzahn99 2005-09-02 20:14:15 UTC Re: Z-Axis Drive - - Tips and Suggestions wthomas@g... 2005-09-03 18:28:25 UTC ReW.E.T.: [CAD_CAM_EDM_DRO] Re: Z-Axis Drive - - Tips and Suggestions