CAD CAM EDM DRO - Yahoo Group Archive

Re: Stepper Motor Winding

Posted by bob_kellock
on 2006-03-01 03:49:20 UTC
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "davelandnni" <daveland@...>
wrote:

> .....
> I have some Superior Electric Steppers that are labeled 2.25V 4.6amp
> They are 6 wire motors. .......
>
> Should I run them in parallel or series connected bipolar mode?

> Thanks
> Dave
>

6 wire motors are normally unipolar. Bipolar motors that can be
configured for parallel or series have 8 wires.

Bob

Discussion Thread

davelandnni 2006-02-25 22:31:37 UTC Stepper Motor Winding teo 2006-02-27 21:08:00 UTC sal Vlad Krupin 2006-02-28 00:20:36 UTC Re: [CAD_CAM_EDM_DRO] Stepper Motor Winding BRIAN FOLEY 2006-02-28 08:30:37 UTC Re: [CAD_CAM_EDM_DRO] sal bob_kellock 2006-03-01 03:49:20 UTC Re: Stepper Motor Winding Alan Marconett 2006-03-01 08:44:53 UTC RE: [CAD_CAM_EDM_DRO] Re: Stepper Motor Winding Paul Kelly 2006-03-01 16:28:10 UTC RE: [CAD_CAM_EDM_DRO] Re: Stepper Motor Winding