Re: CT Transfromer connection
Posted by
caudlet
on 2007-04-15 11:53:34 UTC
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "turbulatordude"
<dave_mucha@...> wrote:
across the outside red and black pair. For 120VAC in wire them in
parallel with black to balck and red to red.
<dave_mucha@...> wrote:
>each.
> Hi all,
>
> I have a 110/220 primary 24vac secondary transfromer from MPJA.
>
> it appears it has two coils for the primary, red and black wire for
>For 220VAC in wire them in series with read to balck with 220VAC
> the question is that of wiring the primary side.
>
> do I use one coil, or parallel the coils ?
>
> Series wiring will have 220 VAC in and 24vac out.
>
> Dave
>
across the outside red and black pair. For 120VAC in wire them in
parallel with black to balck and red to red.
Discussion Thread
turbulatordude
2007-04-15 09:07:53 UTC
CT Transfromer connection
caudlet
2007-04-15 11:53:34 UTC
Re: CT Transfromer connection