CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder?

Posted by Doug Harrison
on 2000-08-13 18:37:29 UTC
> > Just a little more than three percent reduction in pressure per 1000
foot of
> > altitude
>
> That would be about a 15% effect, worth thinking about.
>
> > However, the cylinder gage reads differential pressure so this should
not
> > matter.
>
> But wouldn't that take less gas from the cylinder to get the same
> diameter ballon as sea level?
>
> John Grant
>
If the bottle was filled in Denver it would contain less gas than if it were
filled at sea level because the gage reads the difference between
atmospheric and bottle pressure, not absolute pressure. The design pressure
rating of the bottle is based on this differential pressure and must be
filled accordingly.

Of course this is all purely academic. The difference in atmospheric
pressure between sea level and Denver is substantially less than the
accuracy tolerance of a 3000 psi gage. It would never even show up on the
gage.

Sure is interesting to think about it though. I guess that is why most
engineers never got dates while in college. ;)

Doug

Discussion Thread

JanRwl@A... 2000-08-12 22:24:03 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? JanRwl@A... 2000-08-12 22:29:17 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Jon Elson 2000-08-12 22:35:50 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Doug Harrison 2000-08-13 10:20:44 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Tim Goldstein 2000-08-13 10:58:24 UTC RE: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? John Grant 2000-08-13 12:03:11 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Doug Harrison 2000-08-13 14:10:31 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? ptengin@a... 2000-08-13 14:27:44 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? John Grant 2000-08-13 15:35:04 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Tim Goldstein 2000-08-13 16:52:09 UTC RE: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? JanRwl@A... 2000-08-13 16:54:58 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Doug Harrison 2000-08-13 18:37:29 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? Ejay Hire 2000-08-14 07:20:45 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder? dave engvall 2000-08-14 21:37:32 UTC Re: [CAD_CAM_EDM_DRO] OT: Cubic Feet in a Compressed Gas Cylinder?