CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Re: G201 modifications/update

Posted by Jon Elson
on 2000-10-30 15:35:43 UTC
ballendo@... wrote:

> Ballendo,
>
> The G201 is a STEPPER drive. No fault indicator. No "braking"
> necessary. Duh. Sorry list.

This is not necessarily true. Stepper motors can take advantage of
braking. If you have a large machine, with a lot of moving mass, it can

continue traveling quite a distance if the drive is simply shut off,
without
a dynamic braking mode. It won't make much difference on a Sherline.
Stepper motors can be easily braked in a controlled manner by connecting

a braking resistor where the DC power supply normally feeds the
full-bridge
switches (for a bipolar drive). The regenerated voltage from the motor
will be rectified by the freewheeling diodes and fed to the braking
resistor.

Jon

Discussion Thread

ballendo@y... 2000-10-29 14:30:42 UTC RE: G201 modifications/update Mariss Freimanis 2000-10-29 16:53:57 UTC Re: G201 modifications/update ballendo@y... 2000-10-29 18:39:16 UTC Re: G201 modifications/update ballendo@y... 2000-10-29 18:59:07 UTC Re: G201 modifications/update Jon Elson 2000-10-30 15:35:43 UTC Re: [CAD_CAM_EDM_DRO] Re: G201 modifications/update Mariss Freimanis 2000-10-30 16:22:07 UTC Re: G201 modifications/update Smoke 2000-10-30 16:30:35 UTC Re: [CAD_CAM_EDM_DRO] Re: G201 modifications/update Mariss Freimanis 2000-10-30 17:35:24 UTC Re: G201 modifications/update (P.S.) ballendo@y... 2000-10-30 18:31:22 UTC Re: G201 modifications/update (P.S.) Jon Elson 2000-10-30 21:33:13 UTC Re: [CAD_CAM_EDM_DRO] Re: G201 modifications/update (P.S.) Brian Pitt 2000-10-31 00:19:29 UTC E-Stop was Re: G201 mods/update (P.S.)