Posted by Fred Smith
on 2001-06-10 10:20:09 UTC
--- In CAD_CAM_EDM_DRO@y..., Fitch R. Williams <frwillia@p...> wrote:
> Hi folks,
>
> 1) The coolant channels on the vise are laughably small compared to
> the coolant flow required for adequate chip clearing

With flood coolant you don't need to have chip clearing. Add a
garden hose w/sprayer head to your coolant line to spray the chip out
of the vise after making some serious cuts. You will probably find
that the screen will just get in your way. A t-slot cleaner might be
more useful.

> 2) Splashing off the front of the table, or slinging off the front
of
> the table if using a carbide cutter at high rpm.
>

Without full enclosure at best you will be able to contain the flying
chip from flycutting to only one side of the mill. The coolant is
tough to really contain even with full enclosure, as the slightest
bump to sheet metal and you can develop a leak.


> I gather this is an ascii list - no pictures allowed? Is it allowed
> to use the RCM drop box for pictures related to this list?


There is a picture/files drop box available from the Web site
version, that can be viewed by all, as Tim just made it public access.

Best Regards,

Fred Smtih
IMService

Discussion Thread

Fitch R. Williams 2001-06-10 07:43:33 UTC Coolant control. Chris Stratton 2001-06-10 08:02:04 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Marcus & Eva 2001-06-10 08:28:01 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fred Smith 2001-06-10 10:20:09 UTC Re: Coolant control. dougrasmussen@c... 2001-06-10 10:36:56 UTC Re: Coolant control. machines@n... 2001-06-10 11:51:15 UTC Re: Coolant control. Fitch R. Williams 2001-06-10 19:10:39 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 19:17:17 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. Fitch R. Williams 2001-06-10 19:21:15 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. Jon Elson 2001-06-10 19:50:24 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Jon Elson 2001-06-10 20:04:18 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 20:58:10 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 21:08:57 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Jon Elson 2001-06-10 23:43:14 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. machines@n... 2001-06-11 00:33:08 UTC Re: Coolant control. Fitch R. Williams 2001-06-11 05:02:19 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. dougrasmussen@c... 2001-06-11 07:35:05 UTC Re: Coolant control. Fitch R. Williams 2001-06-11 18:33:03 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control.