CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Coolant control.

on 2001-06-10 19:10:39 UTC
On Sun, 10 Jun 2001 08:32:16 -0700, "Marcus & Eva"
<implmex@...> wrote:

You are correct - its a knee mill.

>I would not piddle around with localized containment, I would build a
>monster containment box around the whole front of the mill with only the
>electronics and electrics poking out.

I've thought hard about your suggestion. Its a good one. I'm
seriously considering adding a flair to the base (just out of ankle
range) to catch what leaks by.

I stopped at Home Depot and picked up some sheet metal. I'll have a
go at it with that first.

Thanks
Fitch
In So. Cal.

The FAQ for RCM is: http://w3.uwyo.edu/~metal
Metal Web News at http://www.metalwebnews.com
The "Drop Box" is at http://www.metalworking.com/

Discussion Thread

Fitch R. Williams 2001-06-10 07:43:33 UTC Coolant control. Chris Stratton 2001-06-10 08:02:04 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Marcus & Eva 2001-06-10 08:28:01 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fred Smith 2001-06-10 10:20:09 UTC Re: Coolant control. dougrasmussen@c... 2001-06-10 10:36:56 UTC Re: Coolant control. machines@n... 2001-06-10 11:51:15 UTC Re: Coolant control. Fitch R. Williams 2001-06-10 19:10:39 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 19:17:17 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. Fitch R. Williams 2001-06-10 19:21:15 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. Jon Elson 2001-06-10 19:50:24 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Jon Elson 2001-06-10 20:04:18 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 20:58:10 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Fitch R. Williams 2001-06-10 21:08:57 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. Jon Elson 2001-06-10 23:43:14 UTC Re: [CAD_CAM_EDM_DRO] Coolant control. machines@n... 2001-06-11 00:33:08 UTC Re: Coolant control. Fitch R. Williams 2001-06-11 05:02:19 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control. dougrasmussen@c... 2001-06-11 07:35:05 UTC Re: Coolant control. Fitch R. Williams 2001-06-11 18:33:03 UTC Re: [CAD_CAM_EDM_DRO] Re: Coolant control.