CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] shielded cable

Posted by Doug Fortune
on 2001-12-19 23:00:05 UTC
npp67420 wrote:
>
> Hello all. Wondering if anyone might know of a mail order source for
> small quantity of shielded cable? Needing 22 or 24 gauge with four
> twisted pair in a flexible cable for connecting axis encoders to the
> drives.

I have 6 pair 20 AWG (individually shielded and drained) wire
(its not on my webpage yet). 20 gauge is good for 7 amps continuous
and so I use it not only for encoder signals, but also singly
(with Gecko 2xx stepper drivers) and in pairs with Gecko 3xx
servo drivers. Over Christmas I'll try to get it (and the
12 pin connectors) onto the web page.

My reasons for using 6 pair is spelled out in a previous post:
http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/message/32734

Send me your adress and I'll mail you a sample. It's .4" dia
so its not skinny cable.

Doug Fortune
http://www.cncKITS.com

Discussion Thread

npp67420 2001-12-19 22:26:00 UTC shielded cable Doug Fortune 2001-12-19 23:00:05 UTC Re: [CAD_CAM_EDM_DRO] shielded cable npp67420 2001-12-20 05:13:35 UTC Re: shielded cable Peter Seddon 2001-12-20 07:05:38 UTC Re: [CAD_CAM_EDM_DRO] Re: shielded cable chewy8833 2001-12-20 07:22:22 UTC Re: shielded cable Drew Rogge 2001-12-20 07:57:23 UTC Re: [CAD_CAM_EDM_DRO] Re: shielded cable