Re: [CAD_CAM_EDM_DRO] Phase Converter
Posted by
wanliker@a...
on 2002-03-26 17:15:46 UTC
In a message dated 3/26/2002 12:24:46 PM Mountain Standard Time,
sirsausage@... writes:
I feel that they have little to recommend them for most applications. The
current to the motors can go thru the roof when you are starting them, and if
anything faults while attempting to start them they can blow parts like
popcorn popping.
Stick with the VFD's you will be much happier.
bill
[Non-text portions of this message have been removed]
sirsausage@... writes:
> If you just want to "start a 15 hp, 3-phase motor, sort of softly", you canI have used 36, 250 HP motors, with softstart on a 13 mile conveyor line, and
> probably use what's commonly called a "soft start". These *are* SCR
> controlled devices which essentially are large light dimmers.
I feel that they have little to recommend them for most applications. The
current to the motors can go thru the roof when you are starting them, and if
anything faults while attempting to start them they can blow parts like
popcorn popping.
Stick with the VFD's you will be much happier.
bill
[Non-text portions of this message have been removed]
Discussion Thread
James Owens
2002-03-25 10:49:39 UTC
Phase Converter
Carlos Guillermo
2002-03-25 14:29:39 UTC
RE: [CAD_CAM_EDM_DRO] Phase Converter
Tim Goldstein
2002-03-25 14:39:41 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Paul Amaranth
2002-03-25 14:43:30 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Carlos Guillermo
2002-03-25 16:27:01 UTC
RE: [CAD_CAM_EDM_DRO] Phase Converter
Raymond Heckert
2002-03-26 06:26:59 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
dp@w...
2002-03-26 10:07:09 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Jon Elson
2002-03-26 10:41:41 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Mr. sausage
2002-03-26 11:22:45 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Paul R. Hvidston
2002-03-26 14:59:12 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
dave_ace_me
2002-03-26 16:11:57 UTC
Re: Phase Converter
wanliker@a...
2002-03-26 17:15:46 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
JanRwl@A...
2002-03-26 19:29:07 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Jon Elson
2002-03-26 22:12:25 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Jon Elson
2002-03-26 22:21:40 UTC
Re: [CAD_CAM_EDM_DRO] Re: Phase Converter
James Owens
2002-03-28 22:03:27 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Jon Elson
2002-03-29 10:12:05 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
James Owens
2002-03-29 13:58:02 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Raymond Heckert
2002-03-29 22:03:54 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter
Jon Elson
2002-03-29 22:58:05 UTC
Re: [CAD_CAM_EDM_DRO] Phase Converter